NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 111 pages

Asbestos inspection plan, NY Department of Labor

Machine-extracted title · confidence 41%

Asbestos Part 56 inspection reference document, NYC.

NYC-WTC_000451646–000451756
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

contractor’s supervisor in the daily project log. Inspection, necessary repairs and documenting is required daily, including days when no Phase I IB or I IC work or support activities are scheduled. (ix) A four (4) foot high construction fence with appropriate signage in compliance with Section 7.4(c) shall be constructed at a minimum of ten (10) feet from the end of the exhaust duct tube, or bank of duct tubes, to surround and control this area from public access. (11) Exhaust Location. The exhaust shall be vented to the outside of the building or structure, to a controllable area away from public access. Each negative pressure ventilation unit exhaust duct shall not terminate less than fifteen (15) feet from a receptor or adversely affect the air intake of any building or structure. If the exhaust duct termination location for this Section cannot be met due to allowable space restrictions or the regulated abatement work area being located above the ground floor, the exhaust shall terminate at the exterior of the building or structure, and all receptors less then fifteen (15) feet from the exterior exhaust duct termination location shall be plasticized with two (2) layers of at least 6 mil polyethylene. Exhaust tubes may be grouped together in banks of no more than five (5) tubes, with each tube exhausting separately and the bank of tubes terminating together at the same controlled area. (i) Exception. HEPA-filtered vacuums used to exhaust Minor size tent enclosure regulated abatement work areas do not require exhausting to the exterior of the building/structure. (12) Booster Exhaust Fan Units. If exhaust ducting in excess of 25 feet in length is attached to any ventilation unit, an unfiltered booster fan of equal flow capacity shall be installed per 25 foot of downstream exhaust ducting from the ventilation unit. Non-collapsible exhaust ducting shall be used between the booster fan units and also between the ventilation units and the booster fan units. Where possible, these booster fan units shall be installed and operated outside of the regulated abatement work area. However, booster fan units installed and operated outside the regulated abatement work area still require installation using GFCI protected temporary power circuits. The power circuit for each booster fan shall be installed to disconnect automatically if upstream HEPA filtered ventilation unit shuts down. (b) Exemption From Ventilation And Use of Negative Pressure Equipment. (1) The use of negative pressure air equipment is not required for the following: (i) OSHA Class II non-friable ACM exterior projects; (ii) asbestos projects where enclosures (i.e. hard walls, tents, etc.) are not required by this Part; (iii) demolition asbestos abatement projects.

12 NYCRR56 Subpart?, Page 63

CITY_21MC100_003243866

NYC-WTC_000451709

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451709Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

NYC-WTC_000446470

State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.

Similar indexed content

Compare copies and versions →