FEMA project worksheet form, 12/19/2001

Machine-extracted title · confidence 40%

Project worksheet disclosure for FEMA-1391-DR-NY, project category E, 12/19/01.

NYC-WTC_000291183
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FEDERAL EMERGENCY MANAGEMENT AGENCY O.M.B. No. 3067-0151 PROJECT WORKSHEET Expires April 30, 2001 i PAPERWORK BURDEN DISCLOSURE NOTICE Public reporting burden for this form is estimated to average 30 minutes. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the needed data, and completing and submitting the forms You are not required to respond to this collection of information unless a valid 0MB control number is displayed in the upper right corner of the forms. Send comments regarding the accuracy of the burden estimate and any suggestions for reducing the burden to Information Collection Management, Federal Emergency Management Agency, 500 C Street, SW, Washington, DC 20472, Paperwork Reduction Project (3067-0151). NOTE: Do not send your completed form to this address. DECLARATION NO: PROJECT NO FIPS NO. DATE CATEGORY FEMA- 1391 -DR- NY 12 061-51000-33 12/19/01 E DAMAGE FACILITY WORK COMPLETE AS OF: Ventilation Cleaning and Repair 09/21/01 : 100% APPLICANT COUNTY New York City Housing Preservation and Development New York LOCATION LATITUDE LONGITUDE 100 Gold Street. New York. NY 10038 DAMAGE DESCRIPTION AND DIMENSIONS The collapse of the World Trade Center (WTC) on September 11, 2001 caused a massive cloud of pulverized concrete and dust to impact neighboring buildings, blocks away from the World Trade Center complex, the building of New York City's, Housing Preservation and Development (HPD) is located at 100 Gold Street, approximately four blocks away;

The dust cloud from the collapse of the WTC directly impacted the building at 100 Gold Street and covered the building with a layer of pulverized debris. Debris and the possible shock wave of the collapse damaged an air intake fan on top of the building. In addition, dust and pulverized debris that settled on the roof of the building clogged the external filters and louvers, thereby creating significant ventilation problems. Dust and pulverized debris entered the fan chamber and insulation. The'ventilation system carried this dust and pulverized debris throughout the building. The lobby of 100 Gold Street was also used as a relief center to provide equipment, food, shelter, change of clothes, and supplies for displaced citizens and rescue personnel working at the WTC site. The dust and debris that impacted 100 Gold Street and brought in by displaced citizens and rescue personnel was possibly contaminated with asbestos.

SCOPE OF WORK Work complete consists of abatement and restoration of the ventilation system on the basis of design, capacity, and function of such systems as existed prior to the disaster and in conformity with applicable standards. This work was conducted by several contractors with specializations in ventilation systems, air quality restoration, and air sampling, monitoring, and analytical testing.

A memorandum from R. Radhakrshnen, P.E. from the City of New York, Department of Environmental Protection, dated Septembei 14, 2001, gave guidance to building owners on procedures for clean-up of asbestos containing materials (see attached document), This memorandum and the U.S. Environmental Protection Agency (EPA) - National Emission Standard for Hazardous Air Pollutants (NESHAP), 40 CFR subpart M, part 61 were used as a basis for the necessary procedures to be performed at all public facilities. Degmor. Inc. provided labor, material, and equipment to perform surface de-contamination and air quality restoration of the air ; handling chamber in the basement, lobby, each floor, and the roof. AAF International provided labor, filers, and materials needed for repairing and cleaning the air intake fan on top of the building. Consulting & Testing Services, Inc; (CTSI) performed air monitoring, testing, and analysis, in accordance to NESHAP, for each floor as part of the building air quality evaluation arid during abatement process. .

Total costs of contractual services for this project total $83,564.70. Costs for contractual service provided by Degmor, Inc total $57,650. Labor, air chaniber fillers and material provided by AAF International total $15,639.70. Costs incurred from "quality : control air sampling performed by CTSI total $10,275.00. ; Costs associated with the Indoor air quality testing and.assessment ($1,500.00), covered underthe CTSI contract, are ineligible in accordancewith FEMA's current PublicAssistanceProgram. '' Documentation to support these costs are in ('Back Up, Do Not Scan", i See Narrative for adiiitional information Does the Scope of Work change the pre-disaster condition at site? □ Yes [3 No Special Consideration issues included? Yes □ No Hazard Mitigation proposal included? r~l Yes No Is there insurance coverage on facility? Yes □ No PROJECT COST ITEM CODE NARRATIVE QUANTITY/UNIT UNIT PRICE COST 1 9025 Contract - Degmor Inc.___________________ 1 I___ LS $ 57,650,00 $ 57,650.00 2 9025 Contract - Consulting & Testing Services, Inc. 1 I___ LS $ 10,275:00 $ 10,275.00 3 9025 Contract - AAF International 1 /LS $ 15,639:70 $ 15,639.70

iSBlSSEW Total $ 83.564.70 PREPARED BY: Dan Martin REMARKS: Project Officer FEMA Form 90-91, SEP 98

CITY_21MC1OO_O1O3131O9

NYC-WTC_000291183

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291183Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279700

FEMA project worksheet for PS 234 school cleanup costs and scope; disaster 1391.

Similar indexed content

Compare copies and versions →