NYC-WTC_000289566
Overview of electron microscopy and X-ray analysis capabilities for asbestos in samples.
4 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Asbestos analysis methodology overview for lab analysis in NYC, 2002.
NYC-WTC_000290270–000290272OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Asbestos Analysis-Methodologies The optical and electron microscope laboratories have been analyzing samples for asbestos since 1978. EMS can supply you with any level of analysis for asbestos including: Transmission Electron Microscopy (TEM) with selected area electron diffraction and energy dispersive x-ray analysis for positive identification of all asbestos structures below SEM, PLM, and PCM resolution. Methodologies for air: - AHERA 40 CFR Part 763 for school clearances • NIOSH 7402 which complements NIOSH 7400 for PCM equivalent size fibers • U.S. EPA Draft Contract 68-02-3266 authored by Yamate, etal (Level 1, U andlU) • ISO 10312 Methodologies for bulk, soil, lung tissue, sediment and waste water which includes quantitative weight percent: • EPA 600/4-83-043 and EPA 600/R-93/116. Methodology for analysis of wipes and microvacs of dust: •ASTM Document D5755 Methodology for analysis of drinking water (for fibers greater than 10 pm in length): •EPA 600/R-94-134 Polarized Light Microscopy (PLM) with dispersion staining for identification of bulk material for asbestos down to 1 %. Methodology for PLM Analysis:
I 0f3 2/8/2002 6:12 PM
NYC-WTC_000290270
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000289566
Overview of electron microscopy and X-ray analysis capabilities for asbestos in samples.
4 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289616
Overview of laboratory methods for asbestos testing across air, bulk, and TEM.
5 shared non-person entities · 1 shared topics · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337923
DOH/OSHA letter discussing coordination of asbestos sampling program at WTC site.
3 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121065
Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.
3 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104616
Fax cover sheet dated March 11, 2002 transmitting documents regarding DEP regulatory compliance at 110 Fulton Street.
4 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342629
Summary of bulk and TEM sampling with lab analysis and quality control.
5 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409508
Documentation of sampling and transfer of asbestos samples from Building 200 per EPA guidelines.
5 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367211
Summary of asbestos air testing results; November 14, 2001 sampling in building and residences.
3 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349352
Preliminary health assessment on highly respirable asbestos aerosols in WTC-contaminated buildings.
5 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409702
Air monitoring results for the [name] Garage with TEM analysis and regulatory acceptance criteria.
5 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409624
Chain-of-custody documenting bulk sampling and air sampling at Building 400 under DEP oversight.
5 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348748
Preliminary health evaluation of asbestos exposure inside contaminated buildings.
5 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000289566
Overview of electron microscopy and X-ray analysis capabilities for asbestos in samples.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094856
Asbestos assessment report for 3 World Financial Center prepared by EMG, Inc. dated April 18, 2002.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095944
Documentation describing analytical methods used for air sample analysis by transmission electron microscopy and dust characterization procedures.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250491
Overview of TEM and PCM methods for asbestos identification and levels of concern.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332101
Scalpel TEM workflow for asbestos, sample prep, and EDX confirmation.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000289566
Overview of electron microscopy and X-ray analysis capabilities for asbestos in samples.
Similar indexed content
Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.
Similar indexed content
NYC-WTC_000289616
Overview of laboratory methods for asbestos testing across air, bulk, and TEM.
Similar indexed content
NYC-WTC_000104616
Fax cover sheet dated March 11, 2002 transmitting documents regarding DEP regulatory compliance at 110 Fulton Street.
Similar indexed content
NYC-WTC_000337923
DOH/OSHA letter discussing coordination of asbestos sampling program at WTC site.
Similar indexed content