NYC 9/11 Public Portal Document Asocscos rtndjyaia f ivzcuivuuiu^ics

•EPA600/R-93/116 • NIOSH 9002

Phase Contrast Microscopy (PCM) for analysis of air filters for fibers. Methodology for airborne fibers: •NIOSH7400A • OSHA ID 160 (fiber count) Scanning Electron Microscope (SEM) for identification of fibers as asbestos with energy dispersive X-ray analysis (EDS) for elemental analysis. There are size and identification limitations. Fibers must be greater than 0.2 pm in diameter, and asbestos fibers must be identified as "suspected asbestos" because there is the possibility of other mineral fibers being present with the same chemical composition. Methodologies: •U.S. EPA Draft, 9-19-86 •ASTM proposed methods.

X-Ray Diffraction Analysis (XRD) for quantification of bulk asbestos-containing materials in the 1% region and when fibers are too small to resolve by PLM Methodology for bulk materials: •NIOSH 9000, quantitative analysis

Superfund method (TEM and PLM) for the determination of reieasable asbestos in soils and bulk materials Methodology: • EPA 540-R-97-028 • Accredited by the U.S. Dept of Commerce, NVLAP, for bulk sample analysis by PLM and air samples by TEM • Certified as a California Hazardous Waste Testing Laboratory for asbestos • Certified by the State of California for asbestos in water by TEM

2 of 3 2/8/2002 6:12 PM

NYC-WTC_000290271

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290271Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →