NYC 9/11 Public Portal Document
(X iWr Mutual™
Liberty
Industrial Hygiene Air Sample Results
Summary for Week of 03-29-02 to 04-05-02
Attached is a summary of the laboratory results completed during the week of March 29, 2002, to
April 5, 2002. The air samples were collected by ATC associates at the World Trade Center site.
The majority of the samples collected by ATC arc “personal samples”, meaning that the worker wore
the sampling device. In addition, the majority of results have shown exposure levels to be below
shift adjusted occupational exposure limits. Those results which were higher than the shift adjusted
occupational exposure limits were:
• Five Quartz concentrations as follows:
• 425 % of the shift adjusted OEL on a Brokk 1500 Operator on level B3, WTC6,
• 325% of the shift adjusted OEL on a Spotter on the surface, NE from Tower 2,
• 163 % of the shift adjusted OEL on a torch cutter on levels Bl & B2, WTC6,
• 154 % of the shift adjusted OEL while breaking concrete on level B2, WTC6,
• 142 % of the shift adjusted OEL on a laborer core drilling slurry wall B2, W58,
WTC6.
One Diesel exhaust fume concentration as follows:
• 252 % of the shift adjusted OEL using a torch in the depression, WTC 2.
In addition, the following results were at or above 50% of the shift adjusted OEL (but below 100%
of the shift adjusted OEL). The operations associated with these results should receive attention to
ensure that these results are an accurate reflection of actual exposures and that feasible steps are
taken in an attempt to ensure that exposures do not elevate over time;
• One Respirable Dust concentration at 58% of the shift adjusted OEL on a torch
cutter on level Bl, WTC6,
• Four Quartz concentrations of 97%, 67%, 54 % and 50 % of the shift adjusted OEL
on tie-back w/slurry wall B2, WTC6, bobcat operator B2, WTC6, an air tech walking all
areas of ground zero, and on a laborer cutting concrete on level B2 SE section, WTC6,
• One Asbestos concentration at 72% of the shift adjusted OEL on a water truck
operator WTC3,
• One Diesel Exhaust Particulate concentration at 51 % of the shift adjusted OEL on
a torch cutter in ihe depression at WTC2.
Noise and catbon monoxide measutements were also made over the same period of time.
• Seven noise measutements exceeded the shift adjusted equivalent 8-hour OEL. None
of these was higher than 100 dBA, as an equivalent 8-hr OET; although two were at 99
dBA as an equivalent 8-hour OEL.
1
CITY_21MC100_008110426
NYC-WTC_000289765
OCR can misread numbers and units. Confirm readings against the page image before using them.