NYC 9/11 Public Portal Document
A.
0^
U.S. Environmental Protection Agency
.4
Air / Bulk / Wipe/ Water Sampling Situation Report
Tuesday, September 25, 2001 (12:00 pm)
Fixed Ambient Air Sampling Locations (Asbestos)
NYC / ER (Sept 22, 4PM - Sept 23,4AM)
0 .'\ll samples below the OSHA PCM standard.
0 5 samples (all perimeter samples) were above the NYC reentry standard for PCM. It
should be noted that no samples exceeded the TEM (AHERA) standard.
NYC / ER (Sept 23, 4AM - Sept 23, 4PM)
o All samples below the OSHA standard and NYC reentry standard for PCM.
o When normalized to 1200 cc volume, 1 sample above the TEM (AHERA) standard
(Location K - comer of Albany and West). Majority of fibers were less than 5 microns.
* NYC /EE.(Sept 23, 2PM - Sept24, 2AM)
O All samples below the OSHA standard and NYC reentry standard for PCM.
o When normalized to 1200 cc volume, 1 sample above the TEM (AHERA) standard
(Location P - Albany and South End). Majority of fibers were less than 5 microns.
Fixed Ambient Air Sampling Locations (Dioxin)
NYC/ER(Sept 16)
No occupational standards available
o Levels do not pose a short-term health concern. However, elevated sufficiently to be of
concern for long-term (chronic exposures).
o ACTION ITEM: Additional monitoring needed for dioxin beyond the debris pile
perimeter.
Ambient Air Sampling Locations (Metals)
mr / ER (Sept 23)
o Ten samples collected within vicinity of ER operations.
o Exceeds the National Ambient Air Quality Standard (1.5 ug/m^ based on a 24 hour, 3
month period) for lead at 3 locations (Barclay/West Broadway, Church/Dey, SW comer
WTC), however does not exceed tire NIOSH standard.
o Chromium levels were identified at 3 locations (Liberty/Broadway, Greenwich/Albany,
Albany/South End) above the EPA Removal Action guidance levels. Does not exceed
the most conservative NIOSH standard (1 ug/m’).
NYC Bulk/Dust Samples
Asbestos (Sept 23) - all samples (11) collected had no detectable levels of asbestos. Samples
were collected around ground zero area at the entry/exit portals for newly deposited material
tracked by personnel and/or vehicles.
Landfill Air Sampling locations (Asbestos)
Sept 23 (6:30AM - 6:30AM)
O Ail samples below OSHA and NYC reentry standards for PCM and TEM (AHERA
standards).
CITY_21MC100_008911772
NYC-WTC_000289585