Air sampling locations, asbestos, Sept 2001

Machine-extracted title · confidence 29%

EPA air sampling results for asbestos at NYC/ER with PCM and TEM exceedances and perimeters.

NYC-WTC_000287620–000287622
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection .Agency Air / Bulk / Wipe/ Water Sampling Situation Report Tuesday, September 25, 2001 (12:00 pm)

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept 22, 4PM - Sept 23, 4AM) O All samples below the OSHA PCM standard. O 5 samples (all perimeter samples) were above the NYC reentry standard for PCM. It should be noted that no samples exceeded the TEM (AHERA) standard.

NYC / ER (Sept 23, 4AM - Sept 23, 4PM) O All samples below the OSH A standard and NYC reentry standard for PCM. O When normalized to 1200 cc volume, 1 sample above the TEM (AHERA) standard (Location K - comer of Albany and West). Majority of fibers were less than 5 microns.

NYC / ER (Sept 23, 2PM - Sept 24, 2AM) o All samples below the OSHA standard and NYC reentry standard for PCM. o When normalized to 1200 cc volume, 1 sample above the TEM (AHERA) standard (Location P - Albany and South End). Majority of fibers were less than 5 microns.

Fixed Ambient Air Sampling Locations (Dioxin)

NYC / ER (Sept 16) o No occupational standards available o Levels do not pose a short-term health concern. However, elevated sufficiently to be of concern for long-term (chronic exposures). o ACTION ITEM: Additional monitoring needed for dioxin beyond the debris pile perimeter.

Ambient Air Sampling Locations (Metals)

NYC/ER (Sept 23) o Ten samples collected within vicinity of ER operations. o Exceeds the National Ambient Air Quality Standard (1.5 ug/m^ based on a 24 hour, 3 month period) for lead at 3 locations (Barclay/West Broadway, Church/Dey, SW comer WTC), however does not exceed the NIOSH standard. o Chromium levels were identified at 3 locations (Liberty/Broadway, Greenwich/Albany, Albany/South End) above the EPA Removal Action guidance levels. Does not exceed the most conservative NIOSH standard (1 ug/m’).

NYC Bulk/Dust Samples

Asbestos (Sept 23) - all samples (11) collected had no detectable levels of asbestos. Samples were collected around ground zero area at the entry/exit portals for newly deposited material tracked by personnel and/or vehicles.

Landfill Air Sampling locations (Asbestos)

Sept 23 (6:30.AM - 6:30AM) O All samples below OSHA and NYC reentry standards for PCM and TEM (AHERA standards).

CITY_21MC100_002417148

NYC-WTC_000287620

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287620Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000130438 · Box DEP Box 53

Draft special investigative audit report on environmental data from the World Trade Center site prepared by IT Corporation.

Similar indexed content

Compare copies and versions →