NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Department of Health Environmental Monitoring report

Machine-extracted title · confidence 45%

Draft environmental monitoring report for WTC area air sampling, Sept 2001.

NYC-WTC_000289526–000289537
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Dust/smoke aerosol after the collapse of the WTC 9/11/2001

added EPA 525 internal standards (Supelco) The dust and smoke extracts, which were was performed by GC with halogen-selec­ to the sample run as quality control checks blown to dryness in conical vials and refrig­ tive electrolytic conductivity detection with for rough quantitation and retention time erated, were analyzed via GC/high-resolu- multipoint calibration, Decachlorodrphenyl quality control. A secondary identification tion mass spectrometry (GC/HRrMS) after ether was used as an internal standard, was performed using.retention time confir­ the addition of an internal standard and 2,2',4.4',5,S',6’-Octachlorobiphenyl was mation with quality control standards, when nonane. We programmed the column tem­ added before extraction as a surrogate stan­ available. We analyzed a 1-pL aliquot of perature to separate the 2,3,7,8-TCDD con­ dard, and results were corrected for its standard with the GC/ITMS system under gener from other TCDD analytes. The tetra recovery (mean ± SD, 68.1 t 2,02). We the same conditions used for samples and congeners had to be eluted from the column confirmed compound identities by GC/,MS quality control samples. Approximately 300 after 20 min for this to occur. The seventeen in the full scare electron ionization mode. semivolatile organic compound standards congeners of interest were then detected None of the target compounds were including EPA 525, 625, and 8270 standards with the HRMS. Wc identified compounds detected in the blank. (Supelco) were injected to build the GC eluting from the GC column by the reten­ retention time library. Wc defined a reten­ tion time reference obtained from the corre­ Results tion time match as an analyte compound sponding labeled isotope and the ion ratio of The general characteristics of each total set­ eluting within ± 5 sec of the standard sample the measured ions during selective ion tled dust and smoke sample are shown in retention time. ,411 reported compounds met response. We calculated the concentration of Table 1; these characteristic.s indicate that these criteria. each congener by using the relative response the composition of major components in Poiychlorinated dioxins (PCDDs) and factors of each native congener to its respec­ each sample were similar, with slight differ­ fiirans (PCDFs). We used U.S. Environmental tive 1.3C12-labelcd congener. ences in total composition for the Market Protection Agency (EPA) Methods 1613 and Standards used in the analyses were con­ Street sample. Generally, the samples were RCRA SW846 Method 8290 for dioxin centration of stock and spiking solutions very light and fluffy, and were white to pink­ analyses {18,I9j. In these methods, a clean containing PCDDs/PCDFs and labeled ish-gray. The general physical appearance of extraction thimble was charged with 5.0 g of compounds. We included a cleanup stan­ the Market Street sample is shown in Figure 100/200-mesh silica topped with TOO g of dard (CI4, 2,3,7,8-TCDD, 0.8 ng/mL) and 2 as an example. The mass of each sample quartz sand. Hic silica layer was left undis­ internal standards (Cly, 1,2,3,4-TCDD, was dominated by nonfibrou.s material and turbed throughout the extraction process. 200 ng/niL; and CI2, 1,2,3,7,8,9-hexaCDD, construction debris, and the Cortlandt and The thimble was placed in a clean extractor 200 ng/niL). Cherry Street samples contained approxi­ with 30-40 mL of toluene in the receiver and BromhiateJ eliphenyl ethers. The analytic mately 0.8% asbestos. In contrast, of the 200—250 mb of toluene in the flask. The wet methodology for detecting brominated mass collected, the Market Street sample sample, filter, and/or disk were loaded and diphenyls and diphenyl ethers have been contained 3.0% asbestos. We found only any nonaqueous liquid removed. The described previously (20). Briefly, we subjected background levels of alpha radionuclide remaining s.'imple was placed in the thimble total dust samples to enhanced solvent extrac­ activity by lii^uid scintillation counter analy­ and manually mixed into the sand layer with tion using methylene chloride. Extracts were sis of all three samples. Beta activity was a clean metal spatula, carefully breaking up purified by size exclusion and silica gel liquid slightly elevated, but not more than twice any large lumps of sample. chromatography. Compound quantification the background level. There were no levels of gamma activity > 1 Bq/g except for natu­ Table 1, General characteristics of settled dust and smoke samples (percent by mass) from the first days rally occurring potassium-40. after the collapse and fires of the WTC. The pH of an aqueous suspension of Street each sample was > 7; the Cortlandt Street Sample Cortlandt Cherry Market sample had a pH of 11.5 Both the Cherry Color Pinkish gray Pinkish gray Pinkish gray arrd Market Street samples Ir.rd a pH of "9 pH 11.5 9.2 93 (Table 1). Significant amounts (-lOfb of the Nonfiber (cement/carbon, %)^ 500 492 37.0 mass) of cellulose were found in all three Glass fiber |%l» 40.0 400 400 samples. This observation is consistent with Cellulose (%) 92 100 20.0 the release of large amounts of disintegrated Chrysotile asbestos (%) ’ 0.8 08 3.0 paper and other products that were origi­ Aerodynamically separated sample (% mass) <2.5 pm diameter 1.12 0.88 1.30 nally pan of the indoor work environments. 2 5-10 pro diameter 035 0.30 0.40 10-53 pm diameter 37 03 46 61 34.69 >53 pm diameter 61.50 5221 63 60 Sieved sample |% mass) <75 pm diameter 38.00 3000 37.00 75-300 pm diameter 46 00 49.00 42.00 >300 pm diameter 16.00 23.00 21.00 Anions/cations (ng/g) Fluoride 220 70 NO Chloride 800 270 220 Nrttate 330 ND NO Sulfate 41,400 35,200 42,100 Calcium 18,200 14,000 17,700 Sodium 400 200 130 Potassium 60 170 270 Figure 2. The general appearance of the bulk dust NO, not detactable collected at the Market Street location east of the ^Values reported to LC- Chen by the Ambient Group, TNC |New York, NY), measured by polarized light microscopy WTC site. Dust samples from the other two sites (400-450x1 were similar in appearance. Magnification = 4x.

Environmental Health Perspectives • voiume 1101 number? I July 2002 707

CITY_21MC100_012182073

NYC-WTC_000289530

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289530Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →