OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Dust/smoke aerosol after the collapse of the WTC - 9/11/2001

added EP,^ 525 internal standards (Supelco) The dust and smoke extracts, which were was performed by GC with halogen-selec­ to the sample run as quality control checks blown to dtyness in conical vials and refrig­ tive electrolytic conductivity detection with for rough quantitation and retention time erated. were analyzed via GC/high-rcsolu- multipoint calibration. Dccachlorodiphenyl quality control. A secondary identification tion mass spectrometry' (GC/HRMS) after ether was used as an internal standard. was performed using retention time confir­ the addition of an internal standard and 2,2',4,4 ',5,6',6'-Octachlorobiphenyl was mation with quality control standards, when nonane. We programmed the column tem­ added before extraction as a surrogate stan­ available. We analyzed a 1-pL aliquot of perature co separate the 2,3,7,8-TCDD con­ dard, and results were corrected for its standard with the GC/ITMS system under gener from other TCDD analytes. The tetra recovery (mean ± SD, 68.1 ± 2.02). We the same conditions used for samples and congeners had to be eluted from the column confirmed compound identities by GC/MS quality control samples. Approximately 300 after 20 min for this to occur. The seventeen in the full scan electron ionization mode. scmivolatile organic compound standards congeners of interest were then detected None of the target compounds were including EPA 525, 625, and 8270 standards with the HRMS. We identified compounds detected in the blank. (Supcico) were injected to build the GC eluting from the GC column by the reten­ retention time library. We defined a reten­ tion time reference obtained from the corre­ Results tion time match as an analyte compound sponding labeled isotope and the ion ratio of The general characteristics of each total set­ eluting within ± 5 sec of the standard sample the measured ions during selective ion tled dust and smoke sample are shown in retention time. All reponed compounds met rcspon.se. We calculated tire concentration of Table I; these characteristics indicate that these criteria. each congener by using the relative response the composition of major components in Polyehlorinateei iJio.rins (PCDDs) factors of each native congener to its respec­ each sample were similar, with slight differ- firans (PCDFs). Wc used U.S. Environmental tive I3C12-labelcd congener. cnces in total composition for tire Market Protection Agency (EPA) Methods 1613 and Standards used in the analyses were con­ Street sample. Generally, the samples were RCRA SW846 Method 8290 for dioxin centration of stock and spiking solutions very light and tiuffy, and were white to pink­ analyses {18,19). In these methods, a clean containing PCDDs/l’CDFs and labeled ish-gray. The general physical appearance of extraction thimble was charged with 5.0 g of compounds. We included a cleanup stan­ the Market Street sample is shown in Figure 100/200-mesh silica topped with 100 g of dard (CI4, 2,3,7,8-TCDD, 0.8 ng/mL) and 2 as an example. The mass of each sample quartz sand. The silica layer w.is left undis­ internal standards (CD, 1,2.3.4-TCDD, was dominated by nonfibrous material and turbed throughout the extraction process. 200 ng/mL; and CI2. 1,2,3,7,8,9-hexaCDD, construction debris, and the Cortlandt and Flic thimble was placed in a clean extractor 200 ng/ml.). Cherry Street samples contained approxi­ with 30-40 mL of toluene in the receiver and BrorniiMtei/ diphctiy/ ethers. The analytic mately 0.8% asbestos. In contrast, of the 200-250 niL of roluene in the flask. The wet methodology for detecting brominated mass collected, the Market Street sample sample, filrer, and/or disk were loaded and diphenyls and diphenyl ethers have becit contained 3.0% asbestos, We found only any nonaqueou.s liquid removed. The described previously {20). Briefly, we subjected background levels of alpha radionuclide remaining sample was placed in the thimble total dust samples to enhanced solvent extrac­ activity by liquid scintillation counter analy­ .rnd manually mixed into the sand layer with tion using methylene chloride. Extracts were sis of all three samples. Beta activity was a clean metal spatula, carefully breaking up purified by size exclusion and silica gel liquid slightly elevated, but not more chan twice any large lumps of .sample. chromatography. Compound quantification the background level. There were no levels of ganinaa activity > 1 Bq/g except for natu­ Table 1. General characteristics of settled dust and smoke samples (percent by mass) from the first days rally occurring potassium-40. after the collapse and fires of the WTC. The pH of an aqueous suspension of Street each sample was > 7; the Cottlandt Street Sample Cortlandt Cherry Market sample had a pH of 11.5. Both the Cherry CoioT Pinkish gray Pinkish gray Pinkish gray and Market Street samples had a pH of ”9 pH 11.5 9.2 93 (Table 1). Significant amounts (=<10% of the Nontiber (cement/carbon. %)^ 500 49.2 37.0 mass) of cellulose were found in all three Glass fiber [%)’ 400 400 400 samples. This observation is consistent with Cellulose 92 100 20.0 the release of large amounts of disintegrated Chrysotile asbestos (%| ■’ 08 . 08 30 paper and other products that were origi­ Aerodynamically separated sample (% mass) <2 5 pm diameter 1.12 083 1.30 nally part of the indoor work environments. 2 5-10 pm diameter 035 030 040 10-53 pm diameter 37.03 4661 34 69 > 53 pm diametet SI.50 5221 63 60 Sieved sample 1% mass) < 75 pm diameter 38.00 3000 37 00 75-300 pm diameter 4S.00 49.00 42.00 > 300 pm d lameter 1600 23.00 21 00 Anions/cations (ng/g) Fluoride 220 70 ND Chloride 800 270 220 Nitrate 330 ND NO Sulfate 41.400 35.200 42,100 Calcium 18.200 14.000 17,700 Sodium 400 200 130 Potassium 60 170 270 Figure 2. The general appearance of the bulk dust ND, not detectable. collected at the Market Street location east of the •Values reported to L.C Chen by the Ambient Group, TNC INew York. NY|, measured by polarrzed light microscopy WTC site. Dust samples from the other two sites 1400-450x1, were similar in appearance. Magnification = 4x.

Environmental Health Perspectives • volume 1101 numbes 71 July 2002 707

CITY_21MC100_006646573

NYC-WTC_000407254

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407254Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →