ELEMENTS (ICPk METHOD 7300, ISSUE 2. dated IS August 1864 - Page 8 of 8

digestion for five minutes. A sample digestion program for 12 samples is presented in the following tabla.

PROGRAM VARIABLES FOR PAINT CHIPS SAMPLE DIGESTION WITH NITRIC ACID

Stage £21 Power 80% 90% 0% Pressure, psi SO 100 0

Run Time, min 10:00 20:00 05:00 Time @ P, mln 05:00 15:00 00:00 Temperature 180‘C 18O’C O’C

Far* Speed 100% 100% 100%

Number of Vessels: 12

Liquid Volume per 5 mL Vessel: Sample Weight: 0.1 g

If the analyst wishes to digest other than two, six, or 12 samples at a time, use different values of power as long as they result In the sama time and temperature conditions. Q. At the end of the microwave program, allow the vessels to cool for a minimum of five minutes before removing them from the microwave unit. If a loss of sample is detected (e.g., material In overflow collection vessel, liquid outside liner), determine the reason for the loss (e.g., loss of vessel seal integrity, use of a digestion time longer than 30 minutes, too large a sample, or improper heating conditions). Once the source of the loss has been corrected, prepare a new sample beginning at Section 2. If insufficient material Is available for reanalysis, dilute remaining digestate and note that some sample Ims may have occurred. f. Uncap and vent each vessel in a fume hood. Add 20 mL reagent water, than reseal vessels and shake to mix thoroughly. Transfer ths sample to an acid-eleenad polyeihylenG bottle. If the digested sample contains particulates which may clog nebulizers or Interfere with injection of the sample into the instrument, allow the sample to settle or filter it:

Settling: Allow the sample to stand until the supernatant Is clear (usually, overnight Is eufflclent). If It does not clear, filler the sample.

Filtering: The filtering apparatus must be thoroughly preclaaned and rinsad with dilute nitric aoid. Filter the sample through quantitative flltar paper into a second aold-cleaned container.

The digeatate is now ready for analysis for elements of interest using the appropriate method.

4. Calculations: Report the concentrations based on the actual weight of the original sample.

NIOSH Manual ofAnelWcal MathodB (NMAM), Founn EUttoc

09/20/01 THU 18:20 [TX/RX NO 87071

CITY_21MC100_008110335

NYC-WTC_000281385

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000281385Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

ICP Elements, Aug 2004

NYC-WTC_000281386

Elements list for ICP analysis; includes aluminum, chromium, etc.

Similar indexed content

NYC-WTC_000070845 · Box DEP Box 61

Chain of custody form for samples submitted to the Westchester County Department of Labs and Research in Valhalla, NY.

Similar indexed content

Compare copies and versions →