NYC 9/11 Public Portal Document NO.43i£ P.3Z14

ELEMENTS dCP): METHOD 73D0, ISSUE 2, dated 16 Auquet 1994 - Pafle 2 of 9

REAGENTS: EQUIPMENT:

1, Nitric add, cone., ultra pure. 1. Sampler; cellulose ester membrane filter, 2. Perchloric acid, cone., ultra pure.* 0.8-pm pore size, 37-mm diameter; in 3. Ashing acid: 4:1 (v/v) HNO3:HC|O4. Mix 4 cassette filter holder. volumes cone. HNO3 with 1 volume cone. 2. Personal sampling pump, 1 to 4 L/min, with HCIO4. flexible connecting tubing. 4. Calibration stock solutions, 1000 ^g/mL. 3. Inductively coupled plasma-atomio amission Commerdally available, or prepared per spectrometer, equipped as apedfied by the Instrument manufacturer's recommendation manufacturer for analysis of elements of (see step 12). interest S, Dilution add, 4% HNO3,1% HCIO4, Add 50 4. Regulator, two-stage, for argon. mL ashing add to 600 mL water; dilute to 1 L. 5. Beakers, Phillips, 12S-mL, or Griffin, 50-mL, 6. Argon. with watchglass covers.** 7. Distilled,deionized water. 6. Volumetric flasks, 10-and 100- mL.** 7. Assorted volumetric pipets as needed.** B. Hotplate, surface temperature 160°C. See SPECIAL PRECAUTIONS. ** Clean all glassware with cone. nitric add and rinse thoroughly in distilled water before use. SPECIAL PRECAUTIONS; Perform all perchloric acid digestions In a perchloric add hood.

SAMPLING:

1. Calibrate each personal sampling pump with a representative sampler in line. 2. Sample at an accurately known fow rate between 1 and 4 L/min for a total sample size of 200 to 2000 L (see Table 1} for TWA measurements. Do not exceed a filter loading of approximately 2 mg total dust Slalpspina: Lalod CagscHes dearlu, Include- Llaib» In a Staarak ba^i'e.. If qeu can 'sample PREPARATION: 3 3. Open the ca6se*Ue*^$^w(^mml trans^er^

4. Adds mL ashing acid. Cover with a watchglass. Let stand 30 min at room temperature. NOTE: Start a reagent blank at this step. . , i ; l“ 5. Heat on hotplate (12O*C) until ca. 0.5 mL remains. IS ihork flfiCfiSSanj. NOTE 1; Recovery of lead from some paint matrices may require other digestion techniques, See Method 7082 (Lead by Flame AAS) for an alternative hotplate digestion procedure or the Appendix for a microwave digestion procedure [8]. NOTE 2; Some species of Al, Be, Co, Cr, LI, Mn, Mo, V, and Zr will not be completely solubilized by this procedure. Alternative solubilization techniques for most of these elements can be found elsewhere [2-7|. For example, aqua regia may be needed for Mn (4,9], 6. Add 2 mL ashing acid and repeat step 5. Repeat this step until the solution Is dear. 7. Remove watchglass and rinse into the beaker with distilled water. 8. Increase the temperature to ISCC and taka the sample to near dryness (ca. 0.5 mL). 9. Dissolve the residue in 2 to 3 mL dilution acid. 10. Transfer the solutions quantitatively to 10-mL volumetric flasks. 11. Dilute to volume with dilution ecid.

CALIBRATION AND QUALITY CONTROL;

12. Calibrate the spectrometer according to the manufacturers recommendations. NOTE; Typically, an acid blank and 10 pg/mL muhlelsment working standards are used. The following multielement combinations are chemically compatible in 4% HNO3/1%

NIOSH Manusl of Analytical MalTicda (NMAM). Fourth EdlUon

09/20/01 THU 18:20 [TX/RX NO 8707]

CITY_21MC100_008110328

NYC-WTC_000281378

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000281378Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

ICP Elements, Aug 2004

NYC-WTC_000281386

Elements list for ICP analysis; includes aluminum, chromium, etc.

Similar indexed content

NYC-WTC_000070845 · Box DEP Box 61

Chain of custody form for samples submitted to the Westchester County Department of Labs and Research in Valhalla, NY.

Similar indexed content

Compare copies and versions →