ICP Elements, Aug 2004

Machine-extracted title · confidence 22%

Elements list for ICP analysis; includes aluminum, chromium, etc.

NYC-WTC_000281386–000281394
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

tSO.432 P.3/14

ELEMENTS (ICP): METHOD 7300, ISSUE 2, dated IS August 1994 - Pafle 2 of 9

REAGENTS: EQUIPMENT: 1. Nitric acid, cone., ultra pure. 1. Sampler: cellulose ester membrane filter, 2. Perchloric acid, cone., ultra pure.* 0.8-pm pora size, 37-mm diameter; in 3, Ashing add: 4:1 (v/v) HNO3:HC|O4. Mix 4 cassette filter holder. volumes cone. HNO3 with 1 volume cone. 2. Personal sampfing pump, 1 to 4 Umin, with HCIO4. flexible connecting tubing. 4. Calibration stock solutions, 1000 pg/mL. 3. Inductively coupled plasma-atomic emission Commercially available, or prepared per spectrometer, equipped as specified by the Instrument manufacturer's recommendation manufacturer for analysis of elements of (see step 12). interest S. Dilution acid, 4% HNO3,1% HCIO4. Add SO 4. Regulator, two-stage, for argon. mL ashing acid to 600 mL water; dilute to 1 L. 5, Beakers, Phillips, 125-mL, or Griffin, 50-mL, e. Argon. with watchglass covers.** 7. Distilled .deionized water. 6. Volumetric flasks, 10-and 100- mL.** 7. Assorted volumetric pipets as needed.** 8. Hotplate, surface temperature 15CC, Sea SPECIAL PRECAUTIONS. •* Clean all glassware with cone. nitric acid and rinse thoroughly In distilled water before use. SPECIAL PRECAUTIONS; Perform all perchloric acid digestions In a perchloric acid hood.

SAMPLING;

1. Calibrate each personal sampling pump with a representative sampler in line. 2, Sample at an accurately known flow rate between 1 and 4 L/min for a total sample size of 200 to 2000 L (see Table 1} for TWA measurements. Do not exceed a filter loading of approximately 2 mg total dust Shipping; Laljcl Cagse-He-s cicsrln . Include- JnaSepara-L. barbie. Jf c«n SAMPLE PREPARATION; Cfillatt 3 taid^ftonoL ) S&wpfc-(wVicrt.'^arc. shauU- 3. Open the casso^e’^sF^S^^f^^n

4. Add 5 mL ashing acid. Cover with s watchglass. Let stand 30 min at room temperature. R*£-,'arraZ^nir, NOTE: Start a reagent blank at this step. » , * S, Heat on hotplate (120*0 untiles, 0,5 mL remains. IS loot fld<£S5S»TJ. NOTE 1: Recovery of lead from some paint matrices may require other digestion techniques. See Method 7082 (Lead by Flame AAS) for an eltematlve hotplate digestion procedure or the Appendix for a microwave digestion procedure (8]. NOTE 2; Some species of Al, Be, Co, Cr, LI, Mn, Mo, V, and Zr will not be completely solubilized by this procedure. Alternative solubilization techniques for most of these elements can be found elsewhere [2-7]. For example, equa regia may be needed for Mn (4,91. 6. Add 2 mL ashing add and repeat step S. Repeal this step until the solution Is dear. 7. Remove watchglass and rinse Into the beaker with distilled water. 8. Increase the temperature to 1S0*C and take the sample to near dryness (ca. 0.5 mL). 9. Dissolve the residue in 2 to 3 mL dilution acid. 10. Transfer the solutions quantitatively to 10-mL volumetric flasks. 11. Dilute to volume with dilution add.

CALIBRATION AND QUALfTY CONTROL:

12. Calibrate the spectrometer according to the manufacturers recommendations. NOTE: Typically, an acid blank and 10 pg/mL multielement working standards are used. The following multielement combinations are chemically compatible In 4% HNO3/1%

NIOSH Manual of AnatyBcal Matfiods (nMAM), Fourth Edition

09/20/01 THU 18:20 [TX/RX NO 8707]

CITY_21MC100_011904217

NYC-WTC_000281387

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000281387Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000070845 · Box DEP Box 61

Chain of custody form for samples submitted to the Westchester County Department of Labs and Research in Valhalla, NY.

Similar indexed content

Compare copies and versions →