NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

OSHA sampling results summary, 02/19/02 (updated)

Machine-extracted title · confidence 54%

Asbestos and rubble-pile exposure data; noise monitoring noted; many samples below PEL.

NYC-WTC_000280326–000280329
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Dioxius: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and around the perimeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins.

Polynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when working on the rubble pile.

Freon R-22, Hydrogen Fluoride & Phosgene: OSHA has taken a total of 202 samples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, arid phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition products of Freon R- 22, hydrofluoric acid (HF) and phosgene showed nd detectable levels.

Inorganic Acids OSHA has taken approximately 97 samples for inorganic acids such as hydrochloric, phosphoric, and sulfuric acids. Two samples for sulfuric acid were found to exceed OSHA’s permissible exposure limit (PEL) of 1 mg/m’.

Page 3 of 4

CITY_21MC100_008910394

NYC-WTC_000280328

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000280328Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →