NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 46 pages

Retrofitting HVAC report, NYC Ground Zero

Machine-extracted title · confidence 41%

New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.

NYC-WTC_000278790–000278835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

microns^®. The present standard has been established by the EPA.

The Bureau of Air Quality Surveillance is responsible for the operation of the ambient air quality monitoring network for the State of New York. The information obtained from the network is used to determine the attainment status of ozone (03), sulfur dioxide (S02), nitrogen oxides (NOx), carbon monoxide (CO), lead, and particulate matter.

The EPA has promulgated health-based standards for the concentration of PM-2.5 in the atmosphere. The 24-hour average Standard has been set at 65 ug/m3 (micrograms per cubic meter). The more stringent EPA requirement of particulate matter of 40 ug/m3 (micrograms per cubic meter) that is applicable to children and adults with asthma or other respiratory health conditions was the intended filtration rate to be achieved with the retrofit filtration program. Daily environmental monitoring of the school’s indoor air quality indicates that these goals have been achieved^'*..

However, a supplementary program has been developed to increase the filtration capability to meet a 95% particulate removal rate at 1 micron.

The proposed program offers significant advantages to the existing classroom unit ventilator HVAC system and does not interfere with the existing exhaust air or smoke purge systems of the building. The barometric relief damper will also insure proper room pressurization should outside air increase over the exhaust air system capabilities. The program consists of the following:

Typical Classroom (725 SF)

The existing HVAC system consisting of two floor mounted unit ventilators with an outside air requirement of 525 cfm will be retrofitted with a program consisting of the following:

• Conversion of one of the two existing floor mounted unit ventilators to a fan coil unit and the elimination of the introduction of outside air by this unit. • Installation of a new vertical unit ventilator having the following characteristics. • Combination Hydronic Heating coil and Chilled water coil • Supply air requirement of 1250 to 1500 cfm depending on classroom size. • Outside air heating capability of 50% of design cfm • Filtering: 2' OdorGuard III pre-filter and 12” cartridge after filter (95% efficiency at 1 micron) • Variable speed fan motor with sufficient design static for the two system filters and supply cfm directly related to room temperature requirements. • Demand ventilation control based on room CO levels.

” A micron is one millionth ot a meter in diameter. See attached ATC air monitoring data and particulate sampling data

A:\6_RetrofmingHVAC.R.CascoTM.ctoc

Page A1 -4

CITY_21MC1OO_O1O2742O7

NYC-WTC_000278820

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278820Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →