NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX =====■ a. .=ja. - ................ - ---------------■■■ -..................................................................................................................................... ' - , ----------------------- -----------------

CONCRETE REPORT ■ent; LIRO Group/NYC DDC Attn; Mike Bailey Report Date; 6/17/2002 Address; Six Aerial Way Report Number Dim Lab#; 1516 Syosset, NY 11791 Date Cast; 5/17/2002 Project; WTC Paving Project Contractor; Tully/Grace JV Concrete Plant; N/A Strength PSI; 4000 Yards Placed; 10.1 sass FIELD INSPECTION REPORT

Pour Location for Set # 1: on one side of Exchange St. bet. William St. & Hanover St.

Pour Location for Set # 2; Pour Location for Set # 3; Tests made in accordance with ASTM; Yes x Not Known Field lnspector(s); Client ASTM C 39 COMPRESSIVE STRENGTH TESTS =sss AREA; 28.27 Cylinder Dia; 6" Cylinder Date Date Slump Air UnitWt. Temp F. Truck Tested Load Strength Required Type 10# Cast Tested C143 Cl 73. C231 C138 C1064 No, Age KN PSI Strength Frac Cylinder Set # 1 Exl 5/17/2002 5/23/2002 4.0 6 368.8 2,930 4. SB® A Ex 2 5/17/2002 6/14/2002 4.0 28 511.9 4,070 4. A Ex 3 5/17/2002 6/14/2002 4.0 28 512.8 4,080 4,000 A

Cylinder Set # 2

Cylinder Set #3

Remarks;

Reviewed By; Laboratory Director Richard Kasparian, P.E are conducted in accordance with ASTM C-39 or AASHTO T-22. By technicians certified by ACI. Municipal Testing is inspectad by the Cement and Concrete Reference Laboratory of The National institute of

standards and Technology and is Accredited by : AASHTO and is Ueensed by. New York City (#19) and by The State of Florida. This report relates only to the item or exact iocation/rtem tested.

not (0 Iha entire constnjction. It can only be reproduced in Ml. and only with Municipal Testing Laboratory, Inc written pennission. Our liability is sthcUy limited to the fee paid.

CITY_21MC100_004662539

NYC-WTC_000278490

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278490Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →