Dioxin analysis case narrative, NYC WTC area

Machine-extracted title · confidence 36%

Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.

NYC-WTC_000278268–000278278
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Triangle Laboratories, Inc. January 17, 2002 Case Narrative 56392

Data Review: The HxCDD recoveiy standard in sample 606 is affected by an interference. The associated labeled standard recoveries are artificially low. However, the areas of the associated standards and the analytes quantitated using these standards are unaffected.

Other Comments: No 2.3,7,8-substituted target analytes were detected in the method blank above the target detection limit (TDL).

Method 8290 contains separate criteria for beginning and ending continuing calibrations. When the ending calibration meets criteria established for the beginning calibration, the average response factor from the initial calibration is used. When the ending calibration only meets the less stringent criteria specified for an ending calibration, the average of the response factor from the beginning and ending calibration is used for analyte and internal standard calculations. Affected samples are identified by the listing of both the beginning and ending calibration filename on the sample report.

The analytical data presented in this report are consistent with the guidelines of EPA Method 8290 Rev. 0 (9/94). Any exceptions have been discussed in the QC Remarks section of this case narrative with emphasis on their effect on the data. Should H. A. Bader, Consultants have any questions or comments regarding this data package, please feel free to contact a Project Scientist, at 919/544-5729.

For Triangle Laboratories, Inc.,

Released by,

Kenneth Varley

Report Preparation Chemist

The total number of pages in the data package is ;

3

CITY_21MC100_003110383

NYC-WTC_000278270

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278270Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC health criteria appendix, Dec 2001

NYC-WTC_000176140

Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.

Similar indexed content

Compare copies and versions →