NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 11 pages

Dioxin analysis case narrative, NYC WTC area

Machine-extracted title · confidence 36%

Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.

NYC-WTC_000278268–000278278
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Triangle Laboratories, Inc. January 17, 2002 Case Narrative 56392

Method S290 Sample Calculations:

Analvte Concentration

The concentration or amount of any analyte is calculated using the following expression. ^0*00 ............... —

Where: ^(o) concentration or amount of a given analyte Ao integrated current for the characteristic ions of the analyte integrated current of the characteristic ions of the corresponding internal standard Qp = amount of internal standard added to the sample before extraction RRF(o) = mean analyte relative response factor from the initial calibration W sample weight or volume

Detection Limits The detection limit reported for a target analyte that is not detected or presents an analyte response that is less than 2.5 limes the background level is calculated by using the following expression. The area of the analyte is replaced by the noise level measured in a region of the chromatogram clear of genuine GC signals. The detection limits represent the maximum possible concentration of a target analyte that could be present without being detected.

-------------------------------- RRF(^, * W Where; = estimated detection limit for a target analyte 2.5 = minimum response required for a GC signal H = sum heights of the noise Hp sum of peak heights of the characteristic ions of the corresponding internal standard Qp = amount of internal standard added to the sample before extraction RRF(e,- mean analyte relative response factor from the initial calibration w sample weight or volume

4

CITY_21MC100_003110384

NYC-WTC_000278271

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278271Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC health criteria appendix, Dec 2001

NYC-WTC_000176140

Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.

Similar indexed content

Compare copies and versions →