NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Dioxin analysis, NYC WTC area testing, Jan 2002

Machine-extracted title · confidence 38%

Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.

NYC-WTC_000278097–000278106
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Triangle Laboratories, Inc. January 10, 2002 Case Nanative 56340

Overview

The samples and associated QC samples were extracted and analyzed according to procedures described in EPA Method 8290 Rev. 0 (9/94). Any particular difficulties encountered during the sample handling by Triangle Laboratories will be discussed in the QC Remarks section below. This report contains results from only the 8290 dioxin/furan analyses of the three wipe samples.

Quality Control Samples

A laboratory method blank, identified as the TLI Blank, was prepared along with the samples.

Laboratory control spike (LCS) and laboratory control spike duplicate (LCSD) samples are extracted and analyzed along with each batch of samples." A report summarizing the analyte recoveries and relative percent differences for these samples is included in the data package.

Quality Control Remarks

This release of this particular set of H. A. Bader, Consultants analytical data by Triangle Laboratories was authorized by the Quality Control Chemist who has reviewed each sample data package following a series of inspections/reviews. When applicable, general deviations from acceptable QC requirements are identified below and comments are made on the effect of these deviations upon the validity and reliability of the results. Specific QC issues associated with this particular project are:

Sample receipt: Four wipe samples were received from H. A. Bader, Consultants at 6.0 “C in good condition on January 08, 2002 and stored in a refrigerator at 4 "C.

Sample Preparation Laboratory: None

Mass Spectrometry: None

Data Review: Due to an extraction error, sample F603 could not be reported. The client was contacted concerning this problem. The client will collect another sample and submit this sample for analysis.

Other Comments: No 2,3,7,8-substituted target analytes were detected in the method blank above the target detection limit (TDL).

2

CITY_21MC100_003110191

NYC-WTC_000278098

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278098Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC health criteria appendix, Dec 2001

NYC-WTC_000176140

Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.

Similar indexed content

Compare copies and versions →