NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
21 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
NYC-WTC_000278097–000278106OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Triangle Laboratories, Inc. January 10. 2002 Case Nanative 56340
Dara Flags
In order to assist with data interpretation, data qualifier flags are used on the final reports. Please note that all data qualifier flags are subjective and are applied as consistently as possible. Each flag has been reviewed by two independent Chemists and the impact of the data qualifier flag on the quality of the data discussed above. The most commonly used flags are:
A ‘B’ flag is used to indicate that an analyte has been detected in the laboratory method blank as well as in an associated field sample. The ‘B’ flag is used only when the concentration of analyte found in the sample is less than 20 times that found in the associated blank. This flag denotes possible contribution of background laboratory contamination to the concentration or amount of that analyte detected in the field sample.
An ‘E’ flag is used to indicate a concentration based on an analyte to internal standard ratio which exceeds the range of the calibration curve. Values which are outside the calibration curve are estimates only.
An ‘I’ flag is used to indicate labeled standards have been interfered with on the GC column by coeluting, interferent peaks. The interference may have caused the standard’s area to be overestimated. All quantitations relative to this standard, therefore, may be underestimated.
A ‘J’ flag is used to indicate a concentration based on an analyte to internal standard ratio which is below the calibration curve. Values which are outside the calibration curve arc estimates only.
A ‘PR’ flag is used to indicate that a GC peak is poorly resolved. This resolution problem may be seen as two closely eluting peaks without a reasonable valley between the peak tops, overly broad peaks, or peaks whose shapes vary greatly from a normal distribution. The concentrations or amounts reported for such peaks are most likely overestimated.
A ‘Q’ flag is used to indicate the presence of QC ion instabilities caused by quantitative interferences.
An ‘RO’ flag is used to indicate that a labeled standard has an ion abundance ratio that is outside of the acceptable QC limits, most likely due to a coeluting interference. This may have caused the percent recovery of the standard to be overestimated. All quantitations versus this standard, therefore, may be underestimated.
An ‘S’ flag indicates that the response of a specific PCDD/PCDF isomer has exceeded the normal dynamic range of the mass spectrometer detection system. The corresponding signal is saturated and the reported analyte concentration is a ‘minimum estimate’. When
5
CITY_21MC100_003110194
NYC-WTC_000278101
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
21 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349144
Volatile organics results summary and LC/MS data for WTC samples.
5 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349045
Chain-of-custody file for environmental samples, including GC/MS data summaries.
5 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132108
Cover letter transmitting lead in dust sampling results for 114 Liberty Street.
6 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176140
Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.
6 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000072019
Document tracking the transfer and custody of samples received by Westchester County Department of Labs & Research.
1 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162521
Lab report forwarding final dioxin wipe results for first 20 post-event samples with TEQ calculations and detection limits.
4 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000072053
Form documenting the chain of custody for samples submitted to the Westchester County Department of Labs & Research.
Similar document embedding; no shared entity or topic indexed. · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105578
Administrative file header identifying records related to the property at 61 Broadway.
3 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132178
Cover letter transmitting lead in dust sampling results for the 12th floor of 114 Liberty Street.
6 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132602
Letter submitting additional air quality monitoring results for several buildings in response to a DEP information request.
6 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132628
A correspondence from Capital Properties providing additional environmental documentation and requesting public review exemptions for submitted data.
6 shared non-person entities · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
Similarity score 0.916 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186429
Cover page for a laboratory report regarding environmental testing at the World Trade Center site on Vesey Street.
Similarity score 0.916 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420647
Plan for Community Air Monitoring at The Greenwich Street properties and related sites.
Similarity score 0.915 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451808
Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.
Similarity score 0.914 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278268
Case narrative for dioxin/dibenzofuran analysis by high-resolution methods, Jan 2002.
Similar indexed content
NYC-WTC_000349144
Volatile organics results summary and LC/MS data for WTC samples.
Similar indexed content
NYC-WTC_000349045
Chain-of-custody file for environmental samples, including GC/MS data summaries.
Similar indexed content
NYC-WTC_000132108
Cover letter transmitting lead in dust sampling results for 114 Liberty Street.
Similar indexed content
NYC-WTC_000176140
Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.
Similar indexed content