Environmental Testing Laboratories, Inc. 208 Route 109, Farmingdale NY 11735 Phone - 631-249-1456 Fax - 631-249-8344 03/05/2002 ORGANIC METHOD QUALIFIERS Q - Qualifier - specified entries and their meanings are as follows:

U - The analytical result is a non-detect.

J - Indicates an estimated value. The concentration reported was detected below the Method Detection Limit.

B - The analyte was found in the associated method blank as well as the sample. It indicates possible/probable blank contamination and warns the data user to take appropriate action.

E - The concentration of the analyte exceeded the calibration range of the instrument.

D - This flag identifies all compounds identified in an analysis at a secondary dilution. In the case of a surrogate this flag indicates a system mointoring compound diluted out.

INORGANIC METHOD QUALIFIERS C - (Concentration) qualifiers are as follows:

B - Entered if the reported value was obtained from a reading that was less than the Contract Required Detection Limit (CRDL) but greater than or equal to the Instrument Detection Limit (IDL).

U - Entered when the analyte was analyzed for, but not detected.

Q - Qualifier specific entries and their meanings are as follows:

E - Reported value is estimated because of the presence of interferences.

M - (Method) qualifiers are as follows:

A - Flame AA

AS - Semi-automated Spectrophotometric

AV - Automated Cold Vapor AA

C - Manual Spectrophotometric

F - Furnace AA

NR - when the analyte is not required to be analyzed.

P - ICP

T - Titrimetric

OTHER QUALIFIERS ND - Not Detected

NA - Not Applicable

* - Outside Expected Range (NYCDEP Table l/ll or Surrogate Limits)

OTHER - All soil and sediment samples are reported on a dry weight basis.

-N1695 - Page 32 of 32

CITY_21MC100_003148466

NYC-WTC_000186460

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186460Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →