Document / 4 pages

PCM fiber lab report, Oct 1998

Machine-extracted title · confidence 21%

Microscopy fiber results report with sample counts and fiber metrics.

NYC-WTC_000278041–000278044
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z z < ( o o co SciLabJob#: 98-10-5697 o u o ID Client Name: Applied Technology Services, Inc. c CT o ro o' oo Q-’ Phase Contrast Microscopy (PCM) Fiber Results "0 o A98113; Fitterman HaU NYC, NY o 5L (M Row Air Fiber Fibers O (D s Sample SciLab # Client Sample # / Location Collected Rate (litcrs/min.) Duration (min.) Filtered (liters) Fields Fibers Density (Fibers/mm ) Cone. (Fibers/cc) TWA o o c pco 3 Q 46 02 100898 46 IO/S/98 5 360 1800 100 6 7.64 0.002 3 (M fM PRP/lOth Floor/By Barclay Side 47 02 100898 47 10/8/98 5 360 1800 100 4 5.10 < 0 001 PRP/IOih Floor/By W. Broadway 48 02 100898 48 10/8/98 $ 360 1800 100 I 1.27 c O OOI PRPZlOlh Floor/By Park Side 49 02 100898 49 10/8/98 5 361 1805 100 7 8.92 0.002 PRP/lOtb Floor/By Greenwich Side 50 02 100898 50 10/8/98 5 360 1800 100 6 7.64 0.002 PRP/lOth Floor/Cleaa Room Decon Reporting Notei: Analyzed by: Anthony Hinton .; Dale Analyzed: 10/9/98 Samples analyzed by NIOSH 7400(A) METHOD, Issue #2. 8/15/94; Limii of Detection a 5.5 fibers per 100 fields or 7 fibers / nim2; This report relates ONLY to the sample analysis expressed I tj as fibers/sq mra of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicuic field area 0.00785 mm2; Dvrahon in minutes; TU'A = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of compliance with the O.Ol fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270, Interlab Sr = 0.450. ELAP #11480 U-

s S

O n H ri ho

s O

I M O O

o sT o I o to

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278044Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →