PCM fiber results, 22 River Terrace, Sep 2001

Machine-extracted title · confidence 32%

SciLab PCM fiber results for 22 River Terrace, Rockrose project, 4-page report.

NYC-WTC_000367153–000367156
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z z ■<

SciLabJob#: 201092773 Page 4 of 4 o o co Client Name: GCI Environmental Advisory, Inc. § c o o 00 Phase Contrast Microscopy (PCM) Fiber Results N01-B4086; Rockrose Development Corp.; 22 River Terrace, NYC/ Amended 9/27/01 ■D c CT o' o> Flow ■D o Air Fiber Fibers SciLab Client Date Rate Duration 3. cn Filtered Fields Fibers Density Cone. TWA 91 CD Sample # Sample # / Location (Fibers/mm^ ) Collected (liters/min.) (min.) (liters) (Fibers/cc) O o o 46 22-9/22-46 9/22/2001 15 62 930 100 4 5.10 <0 003 c 3 Apt 14M Room Kitchen (CAS) CD O 47 22-9/22-47 9/22/2001 15 61 915 100 9 11.46 0.005 Apt 14N Room Kitchen (CAS) 48 22-9/22-48 9/22/2001 15 60 900 100 3 3.82 <0003 Apt 14L Room Kitchen (CAS) 49 22-9/22-49 9/22/2001 15 60 900 100 6 7.64 0.003 Apt 14Q Room Kitchen (CAS) 50 22-9/22-50 9/22/2001 15 60 900 100 10 12 74 0.005 Apt 12A Room Kitchen (CAS) Reporting Notes: (1) Fibers/cc cannot be cakulated^r samples (or blanks) with no air volume Analyzed by Victor Slopac , Dale Analyzed 9/22/2001

Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94, Limit of Dectection= 5 5 fibers per 100 fields or 7 fibers/mm2, This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area, ND = no fibers observed, NA = not analyzed, Walton-Beckett gradicule field area 0 00785 mm2, TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr penod not sampled. Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0 01 fiber/cc standard. Estimated relative standard deviation Intralab Sr=0 405, Interlab Sr=O 45, New York samples (NYSDOH ELAP Lab # 11480), National Institute of Standards and Technology

o H K I to

S o o o I o o to co

o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367156Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →