NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM fiber results, 97-97, LAB

Machine-extracted title · confidence 28%

Microscopy fiber results report (PCM) with sample identifiers and fiber counts.

NYC-WTC_000277970
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I .ciLab Job # .-97-5458 I (

Client Name: Applied Technology Services, Inc. n o Phase Contrast Microscopy (PCM) Fiber Results ft

A97I95: DLJRINGS cc o _ Flow Air Fiber Fibers ab Client Date- B Duration .. 1 Rate , Filtered Fields Fibers Density Cone. TWA >ic Sample # / Location Collccieil (min.) {litcrs/min.) Oilers) (Fibers/mm ) (Fibers/cc) 29100897-01 10/8/97 10 90 900 100 2 2.55 < 0 003 DUR-Basement-in Carmine's Office/ISWA 29100897-02 10/8/97 10 90 900 100 30 38.22 0.016 DUR-Basement-in Computer Room/ISWA 29100897-03 10/8/97 10 90 900 100 4 5.10 < 0.003 DUR-Bosement-in Conidor/ISWA 29100897-04 10/8/97 10 90 900 100 41 52.23 0.022 DUR-Basemenl-Enirancc to Tent/OSWA 29100897-05 10/8/97 10 90 900 100 3 3.82 < 0.003 DUR-Baseiaenl-in Cnmdof/OSWA 29100897-06 10/8/97 10 140 1400 100 4 5.10 < 0.002 DUR-BBsement-by Supply Room/OSWA 39100897-07 10/8/97 0 0 0 100 05 0 64 Blank Footnotes: / 29100897-08 10/8/97 0 0 0 100 0.3 0 64 Blank Footnotes; / porting Notes: ) Fibeis/cc cannot be calculated for samples (or blares) with ^air volume. Analyjed by; Larisa Sryhnaya Date Analyied: 10/9/97 -Samples analyzed by N1OSH 7400(A) METHOD, Issue #ZwlS/94, Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2. This report relates ONLY lo the sample analysis eapiessed as fibctt/sq nun of filter area, ND = no fibers observed; NA = Noi iVialyzed; Walton - Beckett gradicule field area 0.00785 mm2. Duration io minutes; TWA = 81lr TWA calculation assumes MIO exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit fHmployer's Compliance Test) - Calculated as a one sided UCL lo determine 95% certainty nl tumpiiauce with the 0.01 fibei/vc standard: Estimated reialive standard deviation: liilralab .5r = 0.270, Inicriab Sr = 0.450,

o H

to

o o o I o

Ui

NYC-WTC_000277970

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277970Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →