Bacterial and fungal report, MC CUNY

Machine-extracted title · confidence 50%

Bacterial and fungal report for Brooklyn- MC CUNY facility, Mar 15, 2002.

NYC-WTC_000277942–000277943
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Applied Technology Services, Inc. 240 NORTH AVENUE NEW ROCHELLE, NY 10801 (914) 654-0080 / Fax (914) 654-1332

BACTERIAL AND FUNGAL REPORT

On February.' 26, 2002, Applied Technology Services, Inc.(ATS) performed a site inspection to determine the possible presence of fungi and bacterial at Fiterman Hall, Borough of Manhattan Community College(BMCC), City University of New York (CUNY), located at 30 West Broadway, New York, NY. ATS’s services were requested by Narinder Sarin, Chief Project Manager, Dormitory Authority State of New York (DASNY) in conjunction with the ongoing environmental investigation of conditions in the building.

The ATS inspection team consisted of Charles Coppie and Steve VanderWoude.

The inspection revealed water damaged gypsum wallboard and carpeting. Swab and direct read samples were taken of the wallboard and carpeting in the southwest comers of the 11'^ and 12’^’ floors where evidence of water damage was visible. Water damage and fungal growth was also evident on other floors in wallboard on columns.

Results of laboratory analysis indicated high concentrations of bacteria and fungi commonly found in a moist environment. These levels are not a health concern at this time because the building is not occupied. Bioremediation should be performed by properly trained individuals wearing appropriate personal protective equipment.

Removal of the carpet and selected wallboard should take place as part of the remediation project, prior to re-occupancy. Application of a biocidal treatment (corrective and preventive) should also be conducted following removal of affected materials. The concrete floors, steel framing and wallboard, as well as any other affected area should be inspected and tested for bacterial and fungal growth prior to installation of any new material to minimize potential for a recurrence.

Remediation may be started as soon as practical, however testing of affected areas should not take place until the building is watertight.

A copy of the laboratory analysis has been included with this report for your review and reference.

Pictures are included to document existing conditions.

Steve VanderWoude Vice President Applied Technology Services, Inc.

ATS JOB # E02403

CITY_21MC1OO_O11114OO6 NYC-WTC_000277943

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277943Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000277931

Air sampling report for Security Booths at CUNY Fiterman Hall, Mar 14, 2002.

Similar indexed content

NYC-WTC_000186275

Laboratory report detailing bacterial and fungal analysis results for swab samples received in February 2002.

Similar indexed content

Compare copies and versions →