This person had a total system volume of 1,917.8 liter volume in the 16 minutes this graph represents. The total
user volume is 1,594.8 liter minute volume (99.66 liters per minute). Of this total user volume, 1,273.3 liters or
80% flow faster than 85 lit/min (the rate used by NIOSH in testing filters for particle penetration and pressure
drop).
Data
The first consideration is minute volume. The average minute volume for all data is 128 minute liters with a max
of 211. The reason for this high volume is that there is next to no breathing resistance, which allows the subject
to get the volume of air he/she needs to perform the required task. If it can be assumed that the system loss is
17%, the average volume of air used by the subject at the highest-use minute is 106.24 minute liters. This is
28% higher than Dr. J. Kaufman recorded as an average, which is a reasonable expectation without resistance.
Looking at how much of this volume was over 115 lit/min (the NIOSH requirement for PAPR with full face mask),
an average 36% of the volume was above this requirement. More important, looking at how many breaths were
over 115 lit/min, out of all the 6,557 breaths that were recorded for this report, 6,417 breaths or 97.9% were
over 115 lit/min, and would out-breathe a PAPR into negative pressure.
In regard to the particulate filter performance and pressure drop, 78% of the volume was flowing faster than 85
lit/min. This is significant, as all filters are velocity-dependent in regard to filter penetration.