NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

CBIRF respirator study draft, FDNY

Machine-extracted title · confidence 38%

Continued draft pages of respirator device study; content about protection levels.

NYC-WTC_000277520–000277532
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Again looking at how many of the breaths were flowing faster than 85 liters per minute, in 6,537 breaths or 99.69% of the breaths, the air flows faster than 85 lit/min. The average breaths per minute (48) and average heart rate (169) indicate that the subjects worked very hard. Details can be found in Table 2. Table 2 First minute Average Standard Deviation Max Min Lit/min "148 24 211 106 % Volume Over 115 lit/min 45% 10 62% 24% % Volume Flowing faster than 85 lit/min 83% 5 93% 71% Breaths per minute 45 8 61 32 Heart rate 168 16 190 110 Second minute Lit/min 95 23 162 62 % Volume Over 115 lit/min 24% 13 52% 2% % Volume Flowing faster than 85 lit/min 69% 11 89% 43% Breaths per minute 46 7 60 31 Heart rate 164 15 195 125 Third minute Lit/min 140 25 201 76 % Volume Over 115 lit/min 39% 9 56% 20% % Volume Flowing faster than 85 lit/min 82% 5 91% 71% Breaths per minute 53 9 81 32 Heart rate 174 17 199 125 All Data Lit/min 128 33 211 62 % Volume Over 115 lit/min 36% 14 62% 2% % Volume Flowing faster than 85 lit/min 78% 10 93% 43% Breaths per minute 48 9 81 31 Heart rate 169 16 199 110

The importance of PIAF (Peak Inhalation Air Flow) If the PIAF is higher than the supply capability of the PAPR, the performance protection of the PAPR is not higher than its face mask as a negative pressure respirator — in this case, a full face mask, and what is influencing the performance is the capability to seal against the face at all different pressure drops. The performance of the filters also plays a role at this high PIAF. As mentioned above, the particulate part of the filter is influenced by the velocity of the air moving through it. It is commonly accepted that a gas filters capacity against organic compounds is not significantly influenced by higher air flow (pulsating flow). The performance against acid and ammonia has yet to be verified at higher flow (pulsating flow).

The SEA Group Goran Berndtsson Page 7 27/11/2002

CITY_21MC100_007398343

NYC-WTC_000277526

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277526Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

CBIRF respirator study draft forms, FDNY

NYC-WTC_000277507

Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.

Similar indexed content

CBIRF respirator study draft, FDNY

NYC-WTC_000277533

Draft materials of respirator study commissioned by CBIRF; focus on negative pressure respirators and PAPRs.

Similar indexed content

Compare copies and versions →