blue fields are the inhalation phases of a breathing cycle. The red fields are the system losses in maintaining positive pressure All the time, the fan supplies air, also through the exhalation sequence. The volume of those losses varies from 10-30%. The higher percentage losses normally occur at low work rates. The average in this test was 17% (see sample Figure 5). In this report, the higher number is used, as it is the total volume flowing through the filters (as two filters are used, the volume through each filter is half of the total volume). Figure 4 demonstrates how the different figures are calculated. As sampling is done at 50 Hz, the resolution is high. Data can be inspected down to 15 second periods. With this resolution it is easy to see how different each person’s breathing is.

Figure 4

The Total Usffl- Vdume 2?.O Lii re is She Sctai »' / The Total Fltar Vok^me 33.9 Bl ra is the total Lit« betowlheFWlh^thlscaaeitisStterer L i,- ., voluim Calculators (Ur*) Jr

i rAr ■&

.. 1... TtieZ4.4hB<0fM%8Wl!ii. i I i. .. fl

"w:'h.,...

11 <i4 St?

44 successful subjects were sampled for an average of 15 min at 50 Hz = 1,980,000 data points. It was decided to take three minutes from each of the subjects; one in the beginning of the exercise (as the first exercise was the longest in duration), one in the middle and one in the end. There is not a significant difference between the first and the last sample minute. A number of minutes from a number of subjects was then randomly selected to verify the accuracy statistically. Altogether, the final file contains data on 6,557 breaths.

The SEA Group Goran Berndtsson Page 5 27/11/2002

CITY_21MC100_007398364

NYC-WTC_000277550

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277550Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

CBIRF respirator study draft forms, FDNY

NYC-WTC_000277507

Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.

Similar indexed content

CBIRF respirator study draft, FDNY

NYC-WTC_000277533

Draft materials of respirator study commissioned by CBIRF; focus on negative pressure respirators and PAPRs.

Similar indexed content

Compare copies and versions →