NYC-WTC_000277520
Continued draft pages of respirator device study; content about protection levels.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Draft materials of respirator study commissioned by CBIRF; focus on negative pressure respirators and PAPRs.
NYC-WTC_000277533–000277545OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
The 95'" percentile is 427 lit/min, which means that in order to maintain positive pressure all the time for 95% of the US Marines, the PAPR must have an airflow of 427 lit/min (see table 5).
Table 5 Lit/min peak flow SS*" Percentile 427 S?*” Percentile 390 80*" Percentile 368 70*" Percentile 338 60*" Percentile 314 50'" Percentile 290 40*" Percentile 265 30*" Percentile 243 20*" Percentile 217 10‘" Percentile 175
Table 5 shows, for example, that a standard PAPR does not even provide sufficient airflow to the 10‘" percentile.
Conclusions: 1. Inspiratory air flow rates are high for all exercises. This concurs with earlier findings by the author as well as Dr. J. Kaufman, Respiratory Airflow in Working Individuals Wearing Chemical Protection, Mr. I. Holmer, Respiratory flow patterns during physical work with respirators, and Dr. P-O. Astrand, Textbook of Work Physiology. 2. The high work activity required of the Marines generates high PIAF rates, often in excess of the typical test flows, raising the question, how well will the US Marines be protected? 3. Apart from the results seen here comes the question of speech. As talking was not part of the test program, it is know known whether the subjects did talk, and if they did. how loud or for how long. However, the test results indicate that no significant amount of speech took place during this test. As Mr. Ingvar Holmer concludes in his study, talking raises the PIAF by 50%. 4. A full 78% of the inhalation sequence is made up of air that flows faster than 85 lit/min. 5. The capabilities of a filter to filter out contaminants at that high PIAF is not known for some parts of the filter, as they are not tested at this high flow rate as part of standard testing. 6. In order to maintain positive pressure for 95% of all US Marines, an air flow of 427 lit/min is required.
Future work: The test outlined here forms part of a wider spectrum of respirator research, and further work is in progress. The test subjects described here were young and fit. Future research will endeavor to establish the variations occurring in a larger and more diversified cohort. This should serve to give us a broader picture of the relationship between work rate, breathing resistance and PIAF in people of all ages and fitness levels.
The SEA Group Goran Berndtsson Page 9 27/11/2002
CITY_21MC100_007398358
NYC-WTC_000277541
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000277520
Continued draft pages of respirator device study; content about protection levels.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277507
Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277549
Page containing figures and axes related to heart rate; appears to be a lab/monitoring chart.
3 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277546
Draft pages of CBIRF study on filter respirator devices for US Marine personnel; assistance noted.
5 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
5 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
4 shared non-person entities · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
5 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354152
Environmental health summary of NYU NIEHS study on exposure and health outcomes post-WTC.
3 shared non-person entities · similarity 0.904
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242944
ASTM E 981–based air sample test with potency estimation and tracings.
Similar document embedding; no shared entity or topic indexed. · similarity 0.903
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
5 shared non-person entities · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
5 shared non-person entities · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154488
Memo summarizing daily activities including Church Street paving for a memorial service on October 23, 2001.
2 shared non-person entities · 1 shared topics · similarity 0.899
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000277520
Continued draft pages of respirator device study; content about protection levels.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277507
Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277549
Page containing figures and axes related to heart rate; appears to be a lab/monitoring chart.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277507
Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277520
Continued draft pages of respirator device study; content about protection levels.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277549
Page containing figures and axes related to heart rate; appears to be a lab/monitoring chart.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000277520
Continued draft pages of respirator device study; content about protection levels.
Similar indexed content
NYC-WTC_000277507
Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.
Similar indexed content
NYC-WTC_000277549
Page containing figures and axes related to heart rate; appears to be a lab/monitoring chart.
Similar indexed content
NYC-WTC_000277546
Draft pages of CBIRF study on filter respirator devices for US Marine personnel; assistance noted.
Similar indexed content
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content