NYC 9/11 Public Portal Document
The 95*” percentile is 427 lit/min, which means that in order to maintain positive pressure all the time for 95% of
the US Marines, the PAPR must have an airflow of 427 lit/min (see table 5).
Table 5
Lit/min
peak flow
95*'’ Percentile 427
87*” Percentile 390
80*'’ Percentile 368
70*'’ Percentile 338
eo*” Percentile 314
50"’ Percentile 290
AO'” Percentile 265
30**’ Percentile 243
20*’’ Percentile 217
10*” Percentile 175
Table 5 shows, for example, that a standard PAPR does not even provide sufficient airflow to the 10®’ percentile.
Conclusions:
1. Inspiratory air flow rates are high for all exercises. This concurs with earlier findings by the author as well
as Dr. J. Kaufman, Respiratory Airflow in Working Individuals Wearing Chemical Protection, Mr. I. Holmer,
Respiratory flow patterns during physical work with respirators, and Dr. P-0. Astrand, Textbook of Work Physiology.
2. The high work activity required of the Marines generates high PIAF rates, often in excess of the typical
test flows, raising the question, how well will the US Marines be protected?
3. Apart from the results seen here comes the question of speech. As talking was not part of the test
program, it is know known whether the subjects did talk, and if they did, how loud or for how long.
However, the test results indicate that no significant amount of speech took place during this test. As Mr.
Ingvar Holmer concludes in his study, talking raises the PIAF by 50%.
4. A full 78% of the inhalation sequence is made up of air that flows faster than 85 lit/min.
5. The capabilities of a filter to filter out contaminants at that high PIAF is not known for some parts of the
filter, as they are not tested at this high flow rate as part of standard testing.
6. In order to maintain positive pressure for 95% of all US Marines, an air flow of 427 lit/min is required.
Future work:
The test outlined here forms part of a wider spectrum of respirator research, and further work is in progress. The
test subjects described here were young and fit. Future research will endeavor to establish the variations
occurring in a larger and more diversified cohort. This should serve to give us a broader picture of the
relationship between work rate, breathing resistance and PIAF in people of all ages and fitness levels.
The SEA Group
Goran Berndtsson Page 9 27/11/2002
CITY_21MC100_007398368
NYC-WTC_000277554
OCR can misread numbers and units. Confirm readings against the page image before using them.