NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Figure excerpts, FDNY heart rate chart

Machine-extracted title · confidence 32%

Page containing figures and axes related to heart rate; appears to be a lab/monitoring chart.

NYC-WTC_000277549–000277558
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Distribution of Minute Volumes

Individual Minute Volumes ranged between 61.7 and 210.5 litres. All Minutes Volumes therefore exceeded the nominal figure of 28.3 litres by at least a factor of 2.

The 75^^ and 95^'’ percentile Minute Volumes were 151 and 178 litres respectively.

Suggested Conclusions

The results of this study demonstrate conclusively that the current assumptions regarding the validity of respirator test results obtained at flow rates of 85 1/min for negative pressure respirators or 115 1/min for PAPR are inadequate in terms of predicting likely performance for high energy expenditure as observed during the Agility Test performed by the US Marine Corps on test subjects wearing SE 400 AT Positive pressure Demand Filter Respirators.

To provide relevant test data for such activities, it would be necessary to test all respirator components at flow rates of 350 l/min to cover 75% of likely wearer PIAF or 428 1/min to cover 95% of likely wearer PIAF.

It should be stressed that the above study results are corroborated by those of Holmer (2002) and Kaufman (2002).

The SEA Group Goran Berndtsson Page 13 27/11/2002

CITY_21MC100_007398372

NYC-WTC_000277558

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277558Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

CBIRF respirator study draft forms, FDNY

NYC-WTC_000277507

Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.

Similar indexed content

CBIRF respirator study draft, FDNY

NYC-WTC_000277533

Draft materials of respirator study commissioned by CBIRF; focus on negative pressure respirators and PAPRs.

Similar indexed content

Compare copies and versions →