Distribution of Minute Volumes
Individual Minute Volumes ranged between 61.7 and 210.5 litres. All Minutes Volumes therefore
exceeded the nominal figure of 28.3 litres by at least a factor of 2.
The 75^^ and 95^'’ percentile Minute Volumes were 151 and 178 litres respectively.
Suggested Conclusions
The results of this study demonstrate conclusively that the current assumptions regarding the validity of
respirator test results obtained at flow rates of 85 1/min for negative pressure respirators or 115 1/min
for PAPR are inadequate in terms of predicting likely performance for high energy expenditure as
observed during the Agility Test performed by the US Marine Corps on test subjects wearing SE 400
AT Positive pressure Demand Filter Respirators.
To provide relevant test data for such activities, it would be necessary to test all respirator components
at flow rates of 350 l/min to cover 75% of likely wearer PIAF or 428 1/min to cover 95% of likely
wearer PIAF.
It should be stressed that the above study results are corroborated by those of Holmer (2002) and
Kaufman (2002).