Tridymite Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four samples were below the detection limit.

Post Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit. Since all of the samples were below the detection limits after the first cleaning, no additional samples were collected for tridymite.

MMVF Before Cleaning Samples - There were four pre-cleaning wipe samples collected. .The four wipe samples had MMVF detected in concentrations from 286.16 S/cc to 2174.79 S/cc.

Post P' Cleaning Samples - There were three air samples and five wipe samples collected after the first cleaning. All of the air sample results indicate that MMVF was present but at levels below the numeric criterion of 10 S/L. All of the wipe sample results were in the range of 57.23 S/cc to 572.31 S/cc, which is lower than the pre-cleaning range. This indicates the cleaning techniques were effective at reducing MMVF concentrations.

PAHs Before Cleaning Samples - There were four pre-cleaning wipe samples collected. Three of the four samples were below the detection limit with TEF values below he primary numeric criterion. The fourth sample had six PAH compounds detected and the calculated TEF slightly exceeded the primary numeric criterion of 300 pg/m^ with a value of 325.8 pg/m^.

Post J" Cleaning Samples - There were four post-cleaning wipe samples collected. All four samples were below the detection limit, and the TEF for each sample was below the numeric criterion of 300 pg/m\

Total Dust Before Cleaning Samples - There were four pre-cleaning wipe samples collected; however, EPA only requested to have two of the samples analyzed. The results indicate that dust was present in the range of 410,000 pg/m^ to 580,000 pg/m^.

Post J'' Cleaning Samples - There were four post-cleaning wipe samples collected; however, EPA only requested to have two of the samples analyzed. The analyzed sample indicates that dust was present at concentrations higher than the pre-cleaning concentrations. However, total dust does not have a numeric criterion.

Fourth Floor Hallway - The fourth floor hallway is an area with plywood floors and walls made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.

69

CITY_21MC100_0 04205025

NYC-WTC_000276721

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276721Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →