Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for tridymite.
MMVF
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. .The four
wipe samples had MMVF detected in concentrations from 286.16 S/cc to 2174.79 S/cc.
Post P' Cleaning Samples - There were three air samples and five wipe samples collected
after the first cleaning. All of the air sample results indicate that MMVF was present but at
levels below the numeric criterion of 10 S/L. All of the wipe sample results were in the range
of 57.23 S/cc to 572.31 S/cc, which is lower than the pre-cleaning range. This indicates the
cleaning techniques were effective at reducing MMVF concentrations.
PAHs
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. Three of
the four samples were below the detection limit with TEF values below he primary numeric
criterion. The fourth sample had six PAH compounds detected and the calculated TEF
slightly exceeded the primary numeric criterion of 300 pg/m^ with a value of 325.8 pg/m^.
Post J" Cleaning Samples - There were four post-cleaning wipe samples collected. All four
samples were below the detection limit, and the TEF for each sample was below the numeric
criterion of 300 pg/m\
Total Dust
Before Cleaning Samples - There were four pre-cleaning wipe samples collected; however,
EPA only requested to have two of the samples analyzed. The results indicate that dust was
present in the range of 410,000 pg/m^ to 580,000 pg/m^.
Post J'' Cleaning Samples - There were four post-cleaning wipe samples collected; however,
EPA only requested to have two of the samples analyzed. The analyzed sample indicates that
dust was present at concentrations higher than the pre-cleaning concentrations. However,
total dust does not have a numeric criterion.
Fourth Floor Hallway - The fourth floor hallway is an area with plywood floors and walls made of
sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.