that dust was present at concentrations higher than the concentrations reported for the pre
cleaning samples.
Unit 4C - This is a 655 sq. ft. open loft which faces the World Trade Center site. The windows were
blown-in and there was significant dust accumulation in the dwelling. The unit has hardwood floors
and no carpet. All personal possessions to be retained by the tenant were vacuumed and bagged.
Cleaning Method - This unit was cleaned using test method lA. Test method lA used a
Craftsman shop vacuum and Eureka upright for vacuuming the floors and other surfaces. No
HEPA or AFD was used during the cleaning process. In addition, all horizontal surfaces
were wet wiped.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned once.
Supplemental Sampling Activities - The air samples collected for PAH analysis were taken
for reference purposes only. These samples are discussed in the PAH section below.
Asbestos
Before cleaning samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All
four of the micro vacuum samples detected chrysotile, and one of the four micro vacuum
samples detected amosite. Three of the four wipe samples detected chrysotile; however, one
of these samples was below the detection limit. The fourth wipe sample did not detect
chrysotile and was below the detection limit.
Post P' Cleaning Samples - Post-cleaning air, micro vacuum, and wipe samples were
collected for asbestos. The samples were analyzed using PCM, TEM AHERA, and PCMe.
The PCM analysis could not be conducted due to overloading of particulate material. The
TEM AHERA results were above the detection limit but below the secondary numeric
criterion of 0.022 s/cc. Two of the three air samples analyzed using TEM PCMe were below
the numeric criterion of 0.0009 S/cc. The third air sample detected chrysotile and was
present at the numeric criterion of 0.009 S/cc. Since the primary numeric criterion was met,
no additional cleaning was required.
The results of the three micro vacuum samples indicate that asbestos was present at levels
lower than those observed before cleaning.
The results of the five wipe samples indicate that asbestos was present above the detection
level in one of the five samples. The concentrations were lower than the pre-cleaning
concentrations.