Before Cleaning Samples - There were four pre-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed. The results indicate that there was no dust present above the detection limit of 200 pg/m^.

Post J" Cleaning Samples - There were four post-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed. The analyzed sample indicates that dust was present at concentrations higher than the pre-cleaning concentration.

Third Floor Hallway - The third floor hallway is an area with plywood floors, and walls made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.

Cleaning method - This area was cleaned using test method 4A and test method 4B. Test method 4A used industrial HEPA filtered vacuums and an AFD, while test method 4B consisted of a soap and water wet wipe of the ceiling only.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two post-cleaning air samples collected. The two air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM results were all below the secondary numeric criterion of 0.01 f/cc. Similarly, the TEM AHERA results were all below the secondary numeric criterion of 0.022 S/cc. The TEM PCMe results were all below the primary numeric criteria of 0.0009 S/cc with both samples being below the detection limit.

Dioxin Before Cleaning Samples - There were no before cleaning samples collected.

Post J" Cleaning Samples - There were no post-first cleaning samples collected

Gypsum Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two air samples collected after the first cleaning. The results indicate that gypsum was not detected in any sample.

Lead Before Cleaning Samples - There were no before cleaning samples collected.

54

CITY_21MC100_004205010

NYC-WTC_000276706

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276706Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →