E Table 9 Sunynary of Airborne Fibers at Locations Where Asbestos Was Detected in Settled Surface Dust

Outdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLM or TEM)* (PLM)" Sampling‘s (PCM)" 1 Outdoor <1% 22% No 0.001 £/cc 2' Outdoor 1.3% 28% No 0.003 fZcc 5 Outdoor 3.4% 25% No 0.002 f/cc

7 Outdoor 1.7% 35% No <0.001 f/cc 15 Outdoor 1.9% 72% No <0.001 f/cc

27 Outdoor <1% 15% No <0.001 f/cc

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVFin Dust Aggressive Fibers in Air (PLM or TEM)" (PtM)” Sampling' (PCM)**

7 Common <1% 15% No 0.001 f/cc 6 Common <1% 10% No <0.001 f/cc 10 Common 1.5% 20% No 0.002 f/cc 24 Common <1% 5% No 0.001 f/cc 27 Common <1% 10% No <0.001 f/cc

Residential Units in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLM or TEM)” (PLM)'’ Sampling' (PCM/

4 Residence 1 <1% 2% Yes <0.001 f/cc 4 Residence 2 <1% 5% Yes 0.001 f/cc 7 Residence 1 <1% 10% Yes 0.002 f/cc 5 Residence 2 <1% 20% Yes <0.001 f/cc 9 Residence 1 <1% 2% Yes 0.001 f/cc 9 Residence 2 <1% 5% Yes 0.003 f/cc 11 Residence 1 <1% ND Yes <0.001 f/cc 11 Residence 2 1.5% ND Yes <0.001 f/cc 15 Residence 1 <1% ND Yes <0.001 f/cc 27 Residence 1 <1% 10% No <0.001 f/cc

a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Building 2 also had a co-located dust sample; values represent the highest measured result.

61

CITY_21MC100_011108793

NYC-WTC_000275929

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275929Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275930

Outdoor area data for asbestos and SVF residues and air fibers.

Similar indexed content

NYC-WTC_000275928

Air sampling results for fibers, asbestos, and SVF above 59th Street.

Similar indexed content

Compare copies and versions →