NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 137 pages

NYC WTC lab image fragment (City file), 2005

Machine-extracted title · confidence 12%

Lab image sample fragment from NYC WTC file; city labeling present.

NYC-WTC_000445524–000445660
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 9 Summary of Airborne Fibers at Locations Where Asbestos Was Detected in Settled Surface Dust

Outdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)’’ Aggressive Fibers in Air (PLM or TEM)" Sampling^ (PCM)'’

1 Outdoor <1% 22% No 0.001 f/cc

2'= Outdoor 1.3% 28% No 0.003 f/cc

5 Outdoor 3.4% 25% No 0.002 f/cc

7 Outdoor 1.7% 35% No <0.001 f/cc

15 Outdoor 1.9% 72% No <0.001 f/cc 27 Outdoor <1% 15% No <0.001 f/cc

Common / reas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)’’ Aggressive Fibers in Air (PLM or TEM)" Sampling's (PCM)'’

4 Common <1% 15% No 0.001 f/cc

6 Common <1% 10% No <0.001 f/cc

10 Common 1.5% 20% No 0.002 f/cc

24 Common <1% 5% No 0.001 f/cc

27 Common <1% 10% No <0.001 f/cc

Residential Units in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)*’ Aggressive Fibers in Air (PLM or TEM)" Sampling‘s (PCM)'’

4 Residence 1 <1% 2% Yes <0.001 f/cc

4 Residence 2 <1% 5% Yes 0.001 f/cc

5 Residence 1 <1% 10% Yes 0.002 f/cc

5 Residence 2 <1% 20% Yes <0.001 f/cc

9 Residence 1 <1% 2% Yes 0.001 f/cc

9 Residence 2 <1% 5% Yes 0.003 f/cc

11 Residence 1 <1% ND Yes <0.001 f/cc

11 Residence 2 1.5% ND Yes <0.001 f/cc

1.5 Residence 1 <1% ND Yes <0.001 f/cc

27 Residence 1 <1% 10% No <0.001 f/cc

a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used tor settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Building 2 also had a co-located dust sample; values represent the highest measured result.

60

CITY_21MC100_0 07122069

NYC-WTC_000445593

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445593Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

Compare copies and versions →