Table 8: Fiber Results in Air Above 59th Street

Machine-extracted title · confidence 41%

Air sampling results for fibers, asbestos, and SVF above 59th Street.

NYC-WTC_000275928
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 8 Summary of Results for Locations With Airborne Fiber Levels Higher Than Levels in Comparison Areas Above 59th Street.

Air samples were collected and analyzed by phase contrast microscopy for total fibers (NIOSH 7400). All samples with fiber counts higher than the comparison areas above 59th Street were re-analyzed to determine if those fibers were asbestos, synthetic vitreous fibers (SVF), or other material.

Building Aggressive Fibers in Air by Asbestos in Asbestos in SVF in Dust SVF in Air by (Area) Sampling” PCM Dust by PLM Air by TEM by PLM SEM (fZee)” orTEM' (gec)” (gec)” 1 (Residence) No 0.006 ND® <0.001“ 20% 0.000162 2 (Common) No 0.005 ND® <0.001“ 27% 0.000255 79 (Common) No Overloaded' ND® <0.006^ ND Not analyzed 24 (Residence) No 0.005 ND® <0.001“ 10% 0.000037 26 (Common) No 0.004 ND® <0.001“ 5% <0. SlBilB4 26 (Residence) No 0.012 ND® <0.001“ ND <0.00004 a. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. b. f/cc = fibers in each cubic centimeter (cc) of air as determined using phase contrast microscopy (PCM), transmission electron microscopy (TEM), or scanning electron microscopy (SEM) methods. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. c. Value shown represents the highest of polarized light microscopy (PLM) or TEM results for this area. d. The TEM method employed here, National Institute of Occupational Safety and Health (NIOSH) 7402, counts fibers of the same size as those detected by PCM analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in width. e. A building renovation project was occurring near the area of this sampling equipment. Construction dust and building insulation material may have influenced this sample. f. Sample processing of the overloaded filter involved transferring the material to a new filter; this process provides less analytical sensitivity, resulting in a higher detection limit. ___ g. ND = not detected. 1===^===:^====:^^=:

60

CITY_21MC100_011108792

NYC-WTC_000275928

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275928Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275930

Outdoor area data for asbestos and SVF residues and air fibers.

Similar indexed content

NYC-WTC_000275929

Summary of asbestos and SVF detections in Lower Manhattan dust areas.

Similar indexed content

Compare copies and versions →