NYC 9/11 Public Portal Document

Table 8 Summary of Results for Locations With Airborne Fiber Levels Higher Than Levels in Comparison Areas Above 59th Street.

Air samples were collected and analyzed by phase contrast microscopy for total fibers (NIOSH 7400). All samples with fiber counts higher than the comparison areas above 59th Street were re-analyzed to determine if those fibers were asbestos, synthetic vitreous fibers (SVF), or other material.

Building Aggressive Fibers in Air by Asbestos in Asbestos in SVF in Dust SVF in Air by (Area) Sampling” PCM Dust by PLM Air by TEM by PLM SEM (f/cc)*’ or TEM' (Ecc? (f/cc)*’ 1 (Residence) No 0.006 NDS <0.001** 20% 0.000162 2 (Common) No 0.005 ND® <0.001" 27% 0.000255 19 (Coirunon) No Overloaded' ND® <0.006^ ND Not analyzed 24 (Residence) No 0.005 ND® <0.001" 10% 0. BBHIil 37 26 (Common) No 0.004 ND® <0.001'* 5% <0.00004 26 (Residence) No 0.012 ND® <0.001'' ND <0.00004 ■ a. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. b. f/cc = fibers in each cubic centimeter (cc) of air as determined using phase contrast microscopy (PCM), transmission electron microscopy (TEM), or scanning electron microscopy (SEM) methods. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. c. Value shown represents the highest of polai ized light microscopy (PLM) or TEM results for this area. d. The TEM method employed here. National Institute of Occupational Safety and Health (NIOSH) 7402, counts fibers of the same size as those detected by PCM analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in widtli. e. A building renovation project was occurring near the area of this sampling equipment. Construction dust and building insulation material may have influenced this sample. f. Sample processing of the overloaded filter involved transferring the material to a new filter; this process provides less analytical sensitivity, resulting in a higher detection limit. g. ND = not detected. __________

60

CITY_21MC100_011101156

NYC-WTC_000338118

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338118Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →