INTERIOR SURFACES

Wipe samples should be taken of smooth, non-porous surfaces. Wipe samples were used earlier in a study of apartments in Lower Manhattan contaminated by WTC fallout to test for a number of hazardous substances,’ and is a technique that recovers a greater quantity of substances from surfaces than a similar technique using a small micro-vacuum. Wipe sampling has a further advantage in that it is available to a larger number of investigators because it does not require highly specialized equipment. Wipe sampling for asbestos is also compatible with established wipe sampling methods for dioxins and PCB’s, which cannot be sampled with micro vacuum methods.

For porous surfaces, EPA should use ultrasonication extraction laboratory methods '* to efficiently remove particulates from these surfaces so they can be tested. The carpeting and upholstery materials should be subjected to the ultrasonication extraction method, where actual pieces of carpet or upholstery are immersed in solutions to extract particulates. In a study where carpeting had been in use for several years after asbestos contamination, the ultrasonication extraction technique was able to measure 100 times more asbestos than using a micro-vacuum sampling technique for the asbestos. Because this technique destroys the objects being tested, EPA will need to purchase and/or replace items it tests.

EPA should test upholstered furniture and carpeting which has been professionally cleaned with either dry or wet extraction techniques, as well as such items that have been cleaned by homeowners with standard vacuum cleaners. EPA should test furniture and carpeting that has been in use for several months where any contaminants has had an opportunity to work their way deep into the materials.

INTERIOR SURFACES HEALTH-BASED STANDARDS ERA’S WTC TESTING DETECTION LIMITS AND/OR REQUIRED DETECTION LIMITS OTHER TEST METHOD DETECTION LIMITS

UNITS FOR INTERIOR SURFACES ug/m2 = micrograms per squa'e meter; ng/m2 = nanog'ams per square meter; ug/ft2 = micrograms per square foot; s/cm2 = asbestos structures per square centimeter

ASBESTOS (interior surfaces) detection limit low enough to TEM testing by wipe sampling over background no testing of interior surfaces by EPA in WTC evaluation ascertain from one sample of hard smooth surfaces, and any statistically significant ultrasonication extraction of detection limit: Ground Zero Task Force, deviation from background porous/woven surfaces Independent study of 165-4320 s/cm2 apartments in Lower Manhattan, WTC evaluatiorf

o FIBERGLASS (interior surfaces) H detection limit low enough to testing by wipe sampling of over background no testing of interior surfaces by EPA in WTC evaluation K ascertain from one sample hard smooth surfaces, and I any statistically significant ultrasonication extraction of to deviation from background porous/woven surfaces. Analyze along with asbestos by TEM. o o I o

o -6- co cn co o

NYC-WTC_000275346

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275346Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →