The most meaningful asbestos test that a resident can have, whether or not they have a consultant
to take samples, is EPA’s ultrasonication extraction test for carpeting, draperies, or upholstery
fabric. Over 100 times the amount of asbestos will be found in carpet using EPA’s
ultrasonication test, compared to the ASTM microvacuum sampling method.®
An ultrasonication test may be the best way to tell if asbestos is present in a residence or office.
Carpeting and upholstered fabric can be tested to see if it needs abatement, or it can be tested
after abatement to determine whether it was decontaminated. Hard smooth surfaces may show
no asbestos contamination with the ASTM microvacuum method if tested soon after cleaning.
But carpeting cannot be cleaned effectively, and will show any residual asbestos.
My 6/9/02 memorandum, titled Carpet, the Asbestos Reservoir, provides information on how to
compare the results of the test with any increased risks from asbestos exposure. This
memorandum may be found at www.NYenviroLAW.org.
REFERENCES
1. The laboratories were located by sending an email inquiry to all asbestos laboratories certified
under the National Voluntary Laboratory Accreditation Program and listed on NIST website.
Any additional laboratories should contact me so that their laboratory can be included in updated
listing.
2. Millette, J.R.; Clark, P.J.; Brackett, K.A.; Wheeles, R.K. (1993) Methods for the analysis of
carpet samples for asbestos. Environmental Protection Agency, Cincinnati, OH (United States).
Risk Reduction Engineering Lab. (6 pages) NTIS Report Number: PB-93-194355/XAB , EPA
Publication Number EPA-600/J-93/167. Available from the National Technical Information
Service (NTIS) online for no charge at www.NTlS.gov
Millette, J. R., et al. (1994) Appendix 4, Methods for the Analysis of Carpet Samples for
Asbestos. In: Settled Asbestos Dust. Sampling and Analysis, Lewis Publishers, CRC Press.
3. A complete list of all labs certified to perform TEM tests for asbestos is available from the
National Institute for Standards and Technology (NIST) Laboratory Accreditation
Administration, Gaithersburg, MD 20899 (telephone 301-975-4016),
http://ts.nist.gov/ts/htdocs/210/214/scopes/temtm.htm
4. EPA BEGINS WORK ON PILOT WTC CLEANING FOR RELEASE: Wednesday, June
19, 2002. http://www.epa.gOv/wtc/stories/061902.html
Contaminants to be sampled for include asbestos, lead, dioxins, silica, calcite and gypsum,
fibrous glass and PAHs (Polynuclear Aromatic Hydrocarbons), which are common by-products of
combustion. Dust wipes will be used to collect samples from non-porous surfaces and micro vacs
will be used to collect samples from fabrics and other porous materials. Where possible, bulk dust
samples will be collected for testing. EPA will also evaluate various methods for cleaning HVAC
systems. Laboratory data will be evaluated by EPA to determine the efficiency and effectiveness
of each cleanup technique. Personal monitoring will measure possible exposures to the people
doing the cleaning.