HOW TO USE EPA’s ULTRASONICATION EXTRACTION TEST FOR CARPET, DRAPES, AND UPHOLSTERY

The most meaningful asbestos test that a resident can have, whether or not they have a consultant to take samples, is EPA’s ultrasonication extraction test for carpeting, draperies, or upholstery fabric. This method was developed specifically for carpeting by EPA’s Risk Reduction Laboratory.' The method number is EPA 6()C'/J-93/167, the Millette ultrasonication carpet method. Over 100 times the amount of asbestos will be found in carpet using EPA’s ultrasonication test, compared to the ASTM microvacuum sampling method.^

The ultrasonication extraction test does not recjuire any special equipment, such a micro-vacuum pump, or an air testing pump. Therefore, no industrial hygienist or other consultant needs to be hired to do the sampling. The only cost will be the lab fee. However, this means cutting out at least 16 square inches (100 square centimeters) of carpeting or other fabrics and sending it to the laboratory. See below for ideas on how to take samples without incurring unreasonable replacement costs for carpet, drapery, or upholstery.

An ultrasonication test may be the best way to tell if asbestos is present in a residence or office. Carpeting and upholstered fabric can be tested to see if it needs abatement, or it can be tested after abatement Io determine whether it was decontaminated. Hard smooth surfaces may show no asbestos contamination with the ASTM raicrovacuum method if tested soon after cleaning. But carpeting cannot be cleaned effectively, and will show any residual asbestos.

Air testing is problematic for determining whether there is an asbestos problem. The aggressive AHERA TEM clearance test, using a leaf blow'er, may not show any asbestos at all, much less over 70 structures/square millimeter, even when there are extremely high levels of asbestos dust on surfaces. This was found to be true for the Brookfield, Connecticut school system, where schools were cleaned in the year 2000, and the AHERA TEM clearance test showed no problems.’ Recently, however, asbestos dust levels on some surfaces in several schools was several thousand structures per square centimeter ( s/cm’ ), and in two instances over 3 million and 14 million s/cm^.'*

The AHERA TEM clearance test also can be highly erratic, giving very different readings when it is repeated at the same location.’ Furthermore, there is too much temptation to control the results to certify that the area has no asbestos problems.

-3-

CITY_21MC100_002847459

NYC-WTC_000209429

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000209429Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →