NYC-WTC_000317716
NYC/DOH briefing on Freon inventories and potential phosgene formation at WTC.
2 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗Sept 2001 update on Freon R-22 status at WTC site.
NYC-WTC_000275279–000275280OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Odor threshold is between 0.5 ppm and 1.5 ppm.
■ Phosgene gas is a severe respiratory irritant. The onset of severe respiratory distress may be delayed for up to 72 hours, the latent interval depending on the concentration and duration of exposure. Delayed onset of pulmonary edema is characterized by cough, abundant "foamy" sputum, progressive dyspnea, and severe cyanosis. At low levels, phosgene is a mild upper respiratory, eye and skin irritant so an exposed victim may not seek an avenue of escape before lower respiratory damage has occurred.
Treatment: As far as we've been able to determine, there is no effective antidote for phosgene poisoning. In case of known or suspected overexposure to phosgene, first- aid measures must be taken immediately. Overexposed persons should not be permitted unnecessary physical exertion. Contaminated clothing should be removed quickly and the exposed body areas flushed with water. Affected patients may require supportive treatment, including oxygen, bronchodialators, steroids and antibiotics. Because of the often-delayed onset of symptoms following overexposure to phosgene, surveillance of the patient is required for a period following overexposure.
P:\920phosg.doc
CITY_21MC100_006814623
NYC-WTC_000275280
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317716
NYC/DOH briefing on Freon inventories and potential phosgene formation at WTC.
2 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275281
R-22 chemical data and safety notes for WTC freon incident.
1 shared non-person entities · 1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279304
Chronicle of asbestos, noise, and rubble-pile sampling results through 11/17.
2 shared non-person entities · similarity 0.894
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436307
Summary of OSHA asbestos air monitoring across financial district and rubble pile in 2001.
2 shared non-person entities · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195937
Industrial MSDS for FREON 22 chemical product (2008).
1 shared non-person entities · 1 shared topics · similarity 0.900
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388861
Material safety data for Freon 22 (chlorodifluoromethane).
1 shared non-person entities · 1 shared topics · similarity 0.899
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208618
Material safety data sheet for Freon 22 (chlorodifluoromethane) providing chemical identification and handling information.
1 shared non-person entities · 1 shared topics · similarity 0.897
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000341925
Overview of nitrous oxide, sulfur oxides, and metal exposures on rubble pile operations.
2 shared non-person entities · similarity 0.895
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209199
OSHA report summarizing air sampling results for metal oxides, sulfur, nitrogen, and a radiation survey of the rubble pile conducted in October 2001.
2 shared non-person entities · similarity 0.892
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418690
Continued asbestos sampling; upper-limit exceedances reduced after TEM analysis; rubble pile monitoring continues.
2 shared non-person entities · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417627
OSHA asbestos and rubble-pile monitoring results; TEM/PCM findings and employee exposure notes.
2 shared non-person entities · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
3 shared non-person entities · 1 shared topics · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000317716
NYC/DOH briefing on Freon inventories and potential phosgene formation at WTC.
Similarity score 0.924 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094824
EMSL Analytical chain of custody document tracking samples from 100 Wall Street collected on September 14, 2001.
Similarity score 0.912 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321987
DOH/DMH air monitoring on 23rd floor of 225 Broadway; detailed results and table in report.
Similarity score 0.910 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354279
OSHA summary through Dec 11: asbestos samples with ND to .037 f/cc; rubble pile results and 77–77 personal samples.
Similarity score 0.910 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279307
Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.
Similarity score 0.910 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354092
DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.
Similarity score 0.910 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000317716
NYC/DOH briefing on Freon inventories and potential phosgene formation at WTC.
Similar indexed content
NYC-WTC_000275281
R-22 chemical data and safety notes for WTC freon incident.
Similar indexed content
NYC-WTC_000195937
Industrial MSDS for FREON 22 chemical product (2008).
Similar indexed content
NYC-WTC_000388861
Material safety data for Freon 22 (chlorodifluoromethane).
Similar indexed content
NYC-WTC_000208618
Material safety data sheet for Freon 22 (chlorodifluoromethane) providing chemical identification and handling information.