NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 11/17
Asbestos: A total of 652 air monitoring samples for asbestos have been taken. From
9/13 -9/21, 177 samples were taken in the financial district. They were taken on
OSHA personnel as they walked within certain predetermined zones. Results
revealed asbestos concentrations ranging from ND (none detected) to .037 f/cc.,
well below OSHA’s permissible exposure limit (PEL) of .1 f/cc.
After 9/21, sampling focused on the rubble pile and those workers working
on or immediately next to it. 63 of the samples analyzed exceeded OSHA’s
limit via PCM analysis. However, upon further analysis using
discriminating counting methods and/or TEM analysis, the number of
asbestos fibers found dropped dramatically to below detectable levels or
well below .1 f/cc.
Carbon Monoxide: A total of 47 personal samples of workers on the rubble pile showed results
ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible
exposure limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve
personal samples have been conducted on employees performing (or
working near) various operations such as jack hammering. Employee’s
exposure to the noise range from 80.6 dBA to 89 dBA. OSHA’s
permissible noise exposure for construction is 90 dBA
Respirable
Silica: The overwhelming majority of the 247 silica samples show no detectable
levels of airborne silica. However, the highest sample result was
approximately nine times the OSHA limit on pre-drillers working on the
bathtub wall. The only other exposures that appear to be over the PEL
level were approximately twice the OSHA limit. These two exposures
occurred during: 1) rubble removal and loading operations near the Winter
Garden; and 2) during the breaking up of concrete in the pit. All of the
work areas where apparent overexposures to silica occurred were in the
rubble pile; an area where OSHA continues to encourage the use of
respiratory protection.
Volatile Organic
Compounds: OSHA has taken 431 samples for (VOCs) such as acetaldehyde, acrolein,
acrylonitrile, benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone, isocyanates
(e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene,
trichloroethylene, vinyl chloride, and xylene. Screening samples initially showed
elevated levels of some organic chemicals resulting from the fires burning in the
1
CITY_21MC100_008897436
NYC-WTC_000417627
OCR can misread numbers and units. Confirm readings against the page image before using them.