Air Monitoring Results: 225 Broadway, Oct 2001

Machine-extracted title · confidence 28%

DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.

NYC-WTC_000354092–000354096
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Of interest, no levels of irritant substances were detected. In general, irritant contaminants/ substances/agents which are relatively insoluble in water (H2O), such as phosgene, ozone, and oxides of nitrogen (NOx) exert effect on the lower respiratory tract. Essentially, the less soluble the substance is in ITO. the deeper and more delayed its irritant effect. Substances that are highly soluble in H2O, such as ammonia and sulfur dioxide, exert effect on the upper respiratory tract. The extent to which the irritant substances may cause adverse health effects depends on the concentrations, duration of exposure, toxicity, and solubility in H2O.

Carbon Monoxide Levels

Of interest, no CO levels were detected within the space despite continuous combustion of materials in the surrounding areas of the World Trade Center. CO is produced by incomplete combustion. The PEL 8hr (TWA) is 35 ppm, ceiling exposure limit (C) is 200 ppm, and the immediately dangerous to life and health limit (IDLH) is 1200 ppm. Based on this finding, neither personal air monitoring with respect to carbon monoxide, methylene chloride nor biological monitoring with respect to metabolites such as CoHb are warranted. A background level of CO is approximately 0.19 ppm.

Carbon Dioxide & Oxygen Levels

CO2 levels within the range of 300 ppm and 350 ppm were detected. These levels were well below the PEL of 5000 ppm. Background level of CO2 is approximately 350 ppm.

The O2 level was 21% (normal). The level suggests that the air was neither deficient nor enriched. For breathing purposes, air should not contain less than 19.4% oxygen or not exceed 23.5 % oxygen.

Thermal Comfort

Temp and RH ranged from 73.7 to 75.7 and 30% - 31 % respectively. Temp and RH were maintained within recommended guidelines. RH below 20% is associated with mucous membrane irritation.

Ventilation

Air velocity measurements at the ceiling supply diffusers ranged from 18 fpm to 310 fpm. With the exception of the air handling (AHU) which serves Classroom #1, the measurements indicated that the mechanical system that serves the space was turn off. Smoke tests at the ceiling diffusers further confirmed this finding. This finding is not unusual since in cases where ambient exposure to air contaminants are suspected, the ventilation mechanical system is usually turned off as a precautionary measure to avoid a pathway for cross-contamination, distribution, and re-distribution of possible contaminated air. Such mechanical systems are designed to provide at least 20% “fresh” outdoor air and 80% re-circulated air.

CITY_21MC100_006717302

NYC-WTC_000354094

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354094Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279307

Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.

Similar indexed content

NYC-WTC_000354112

DOHMH preliminary summary of IAQ measurements on 22nd floor at 225 Broadway.

Similar indexed content

Compare copies and versions →