AMBIENT AIR AND DUST SAMPLING PROTOCOL for STUYVESANT H.S. Page 6 ofS ,

• Second floor lobby - one sample during the school day

• Pool-one sample during the school day

• Cafeteria - one sample during the school day

• Gymnasium - one sample during the school day

• Auditorium - one sample during the school day

» Classroom with north side unit ventilators - one sample immediately after the last class

® Classroom with east side unit ventilators - one sample immediately after the last class

• Classroom with south side unit ventilators-one sample immediately after the last class

o Hallways - 2 samples immediately after the last class. « All sample collected shall be analyzed utilizing the NIOSH 7500 method for respirable silica.

Since, there are no regulatory standards for Mineral Dust in non-industrial buildings, such as offices and schools at this time, the OSHA standard 1910.1000 TABLE Z-3 shall be utilized (per the request of PA consultant).

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant within 72 hours from the collection day.

In the event that unsatisfactory results are obtained, the following actions are to be implemented:

1. Perform general dust clean up of all areas/classrooms with unsatisfactory results. 2. Re-test said areas following clean up. 3. Floor mats and/or other dust control devises shall be placed at points of entry.

Actions 1,2 shall be repeated until satisfactory results are obtained.

DIOXIN WIPE SAMPLES

1. Inside mixed air plenum of an air handling unit.l l'^ floor MER - one sample 2. Ground floor entrance lobby (wall) - one wipe sample 3. 2"" floor entrance lobby (wall) - one wipe sample

All sample collected shall be analyzed utilizing the EPA 8290 PCDD/DF Dioxin Furan method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 15 business days from the day of sampling.

CITY_21MC1OO_OO9O179O2 NYC-WTC_000274913

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274913Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385863

Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.

Similar indexed content

Compare copies and versions →