AMBIENT AIR AND DUST SAMPLING PROTOCOL for STUYVESANT H.S. Page 7 of8

In the event that any.one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

PCO/IPE SAMPLES

4. Inside mixed air plenum of an air handling unit,11'*’ floor MER - one sample 5, 1®* Floor lobby (wall) - one wipe sample 6. 2"'* floor entrance lobby (wall) - one wipe sample

All sample collected shall be analyzed utilizing the EPA 8081 method.

Results from samples collected shall be reported to BOE, LIFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parlies will assess the situation and implement the appropriate response action(s).

HEAVY METAL AIR SAMPLES

1. 11 Floor Roof - one sample 2. 1 Floor lobby - one sample 3. 2"“ Floor lobby - one sample

All sample collected shall be analyzed utilizing NIOSH 7300 method for Al, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Ni, Zn and NIOSH 6009 method for Hg.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactoryBOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

TVOCs AIR SAMPLES

1. Il'f'Floor Roof-one sample 2. r‘ Floor lobby-one sample 3. 2"'^ Floor lobby - one sample

All sample collected shall be analyzed utilizing Hydrocarbon Scan (16+A&B) OSHA 7 method.

Results from samples collected shall be reported to BOE, LIFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactoryBOE will immediately notify the LIFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

CITY_21MC100_009017903 NYC-VVTC_000274914

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274914Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385863

Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.

Similar indexed content

Compare copies and versions →