Summary of Asbestos Sampling Results
36 N. Moore Street, New York, N.Y. 10013
Date sampled: November 27, 2001
Four locations were sampled at your building: inside two private residences, an indoor common
area (e.g., a lobby or hallway), and a nearby outdoor area (see tables below for sampling results).
One air sample was collected in each of the four locations and one settled dust sample was
collected at each of the indoor locations.
Air samples were collected using vacuum pumps to draw air past a filter that was suspended at
the height of a person’s breathing level. Outdoor dust and debris samples were collected by
placing visible material in a container. Indoor dust and debris samples were collected on a filter
by vacuuming surfaces. The collected material was weighed, viewed under a microscope, and/or
chemically processed to determine the types and quantities of substances present. The materials
are being analyzed for fibers such as asbestos, fiberglass, synthetics (e.g. man-made materials such
as nylon and polyester), cellulose (e g. cotton, paper), silica, and for other minerals and small
particles.
ASBESTOS AIR TEST RESULTS
The air samples tested from directly outside, in the lobby of your building, and in the apartments
were taken during normal daily activity. All air samples were examined in a laboratory for fibers
using the Phase Contrast Microscopy (PCM) method.
No fibers were detected in three of the four air samples taken. However, the air sample from the
first floor lobby could not be analyzed for fibers by PCM, and was reported as “overloaded” with
dust. This sample was located across the hall from an elevator that was undergoing renovations.
The dust generated during renovations may partially explain why the sample was overloaded.
When examined by Transmission Electron Microscopy (TEM), asbestos fibers were not identified
and the resulting air concentration was reported as < 0.006 free’. In the homes above 59“' Street,
levels of fibers found in the air ranged from less than 0.001 free to 0.003 free. All of the
remaining air samples in this building fall within this range.
1 There was too much material on the filter to properly count fibers using PCM and the result was reported
as “overloaded” with dust. When a filter is overloaded, an indirect method of analysis is used to estimate
the number of fibers. This involves removing a portion of the filter, transferring it to another filter, and
counting fibers using Transmission Electron Microscopy (TEM). The results of the indirect method did not
detect asbestos fibers. Because the original material in the sample is handled and transferred in the lab,
some of the ability to calculate very low levels of asbestos is lost. This is why the detection limit (<0.006)
is greater for this sample than the others collected in your building.