NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS!
Method: /HERA Final Rule, 3PA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Projec:t/Site: New Stuyv^esant R.S., 34 5 Chambers St., NY, NY TEM Sample No.: 5756 - 62155
Exterior fc I^iterior of Building & Roof
Date Received10/24/01 Grid Openings Analyzed:__ 4
Project Sample No. Average Grid Opening: 106.00 um
Axr Volume _JJ441ixexj; Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm. diam. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Areti: 365 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqiTi/m?
Chrysotile Asbestos 0 0 0 0 0 0 0.0 O.OCOO 0
Amphibole Asbestos C 0 0 0 0 0 0.0 0.0000 0
Ambiguous C 0 0 0 0 0 0.0 0.0000 0
Total asb«jstos (includes ambiguous structures) 0 0 0.0 o.oooc c
Non-Asbestos 0 0 0 0 0 0 0.0 o.oooc N/A
No Identification 0 0 0 0 0 0 0.0 o.oooc N/A
Totals (Ail Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Ronan Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CITY_21MC100_003107265
NYC-WTC_000274165
OCR can misread numbers and units. Confirm readings against the page image before using them.