NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification L>y Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AIIERA final Rule, EPA Federal Register (4C CFR, Part 763), Vol. 52, No. 210, October 30, 19B7
Sample Identification Analysis Parameters
Project/Sit.e: New Stuyvesant E.S, 345 Chambers St., NY, NY TEM Sample No.; 5784 62399
Exterior & Interior of Building & Roof
Date Received: 10/27/01 Grid Openings Analyzed;__4
Project Scimple No. : 14 Average Grid Opening: 106.00 um
Air Volume:: 1928 liteis Total Area Analyzed y 0^£45£nii^
Filter Typ'e: MCE 25 min dian,., Pore Size; 0.45 um Analytical Sensitivity: 22;2 s2mr^
Effective Aree: 385 mm2 C.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fiberf Bundles Clusters Struct. Struct >=5um Struct/mrr.2 Struct/cc ngrr./rr.S
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 C.0 0.0000 0
Ambiguous C 0 0 0 0 0 C.0 0.0000 c
Total asbestos (includes anbiguous structures) 0 0 0.0 0.0003 0
Non-Asbest;o£ C 0 0 9 0 C 0.0 0 . 0000 N/A
No Identification 0 0 0 0 C 0.0 0.0000 N/A
Totals (Ail Structures) 0 c 0.0 0.0090 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473431
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248347