Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN S5414
'ace Analytical__________ Method 8290 Analysis Results
Tel; 612-607-1700
Fax: SI 2- 607-6^^4
/
Client - ATC
Client's Sample ID ATC-1108-04
Lab Sample ID 103124707
Filename U11114A_14
Injected By BAL
Total Amount Extracted 1 Sample Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 11/08/2001
ICAL Date 11/10/2001 Received 11/09/2001
CCal Filename(s) U11114A_01 & U11114A_16 Extracted 11/10/2001
Method Blank ID BLANK-1326 Analyzed 11/14/2001 20:02
Native Cone ElUlPC LRL Internal ng's Percent
Isomers ng/S ng/S ng/S Standards Added Recovery
2,3.7,8-TCDF ND 0,00200 2,3,7,8-TCDF-13C 2.00 91
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 69
1,2,3,7,8-PeCDF-13C 2.00 89
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 84
Total TCDD ND 0.00200 1,2,3.7,8-PeCDD-13C 2.00 73
1,2,3,4.7,8-HxCDF-13C 2.00 110
1,2,3,7,S-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 87
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 98
Total PeCDF ND 0.01000 1,2.3,7,8,9-HxCDF-13C 2.00 92
1,2,3,4,7,8-HxCDD-13C 2.00 89
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 92
Total PeCDD ND 0.01000 1,2,3,4,6.7,8-HpCDF-13C 2.00 76
1,2,3,4,7,8,9-HpCDF-13C 2.00 61
1.2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 68
1,2,3.6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 81
2,3,4,6,7,8-HxCDF ND 0.01000
1.2,3,7,8,9-HxCDF ND 0.01000 1.2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4.7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0,01000
Total HxCDD ND 0.01000
1,2.3,4.6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2.3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.00 ng/S
Total HpCDF ND 0,01000 (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD ND 0,02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals Include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 01-1050848
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003101484
NYC-WTC_000272131