NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Eim Street - Suite 200
Minneapolis. MN 55414
'ace Analytical__________ Method 8290 Analysis Results
Tsi: 612-607-1700
Fax' 512- 607-6444
Client - ATC
Client's Sample ID ATC-1108-03
Lab Sample ID 103124699
Filename U11114A_13
Injected By BAL
Total Amount Extracted 1 Sample Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 11/08/2001
ICAL Date 11/10/2001 Received 11/09/2001
CCal Filename(s} U11114A_O1 &U11114A_16 Extracted 11/10/2001
Method Blank ID BLANK-1326 Analyzed 11/14/2001 19:11
Native Cone EMPC LRU Internal ng's Percent
Isomers ng/S ng/S ng/S Standards Added Recovery
2,3,7,8-TCDF 0.0047 0.00200 J 2,3,7,8-TCDF-13C 2.00 91
Total TCDF 0.0850 ---- 0.00200 2,3,7.8-TCDD-13C 2.00 73
1,2,3,7,8-PeCDF-13C 2.00 83
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 80
Total TCDD 0,1400 0.00200 1,2,3.7,8-PeCDD-13C 2.00 73
1,2,3,4,7,8’HxCDF-13C 2.00 108
1.2,3,7,8-PeCDF ND 0.01 1,2,3,6,7,8-HxCDF-13C 2.00 69
2,3,4,7,8-PeCDF ND 0.01 2,3,4,6,7,8-HxCDF-13C 2.00 93
Total PeCDF 0,0230 0.01 J 1,2,3,7,8.9-HxCDF-13C 2.00 86
1,2,3.4,7,8-HxCDD-13C 2.00 90
1,2,3,7,8-PeCDD ND 0.01 1,2,3,6,7,8-HxCDD-13C 2.00 90
Total PeCDD 0.1300 0.01 B 1,2,3,4,6,7,8-HpCDF-13C
1,2.3,4,7,8,9-HpCDF-13C
2.00
2.00
74
60
1,2,3,4,7,8-HxCDF ND 0.01 1,2,3,4,6,7,8-HpCDD-13C 2,00 66
1,2,3,6,7,8-HxCDF ND 0,01 OCDD-13C 4,00 58
2,3,4,6,7,8-HxCDF ND 0,01
1.2,3,7,8,9-HxCDF ND 0,01 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0,0370 0,01 J 1,2,3,7,8,9-HxCDD-13C 2,00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 76
1,2,3,6,7.8-HxCDD ND 0.01000
F 1,2,3,7,8,9-HxCDD ND 0,01
Total HxCDD 0.1300 0.01000
1,2,3,4,6,7,8-HpCDF 0.0250 0.01 J Total 2,3,7,8-TCDD
1,2,3,4,7.8.9-HpCDF ND 0.01 Equivalence: 0,0014 ng/S
Total HpCDF 0.0250 0.01 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0410 0.01 J
Total HpCDD 0.0830 0.01
OCDF ND 0.02000
OCDD 0,3100 0.02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the caiibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 01-1050848
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC1OO_OO31O1483
NYC-WTC_000272130
OCR can misread numbers and units. Confirm readings against the page image before using them.